C4d staining of renal allograft biopsies: a comparative analysis of different staining techniques


Seemayer, Christian A; Gaspert, Ariana; Nickeleit, Volker; Mihatsch, Michael J (2007). C4d staining of renal allograft biopsies: a comparative analysis of different staining techniques. Nephrology, Dialysis, Transplantation, 22(2):568-576.

Abstract

BACKGROUND: Detection of C4d along peritubular capillaries (PTC) in renal allograft biopsies is an independent prognostic marker of poor long-term graft survival. It is typically associated with circulating donor-specific antibodies. Since only little information is available on the best technique to stain C4d, we compared the two methods most often used for detecting C4d in renal allograft specimens.
METHODS: We investigated the expression of C4d along PTC in 64 renal allograft biopsies using a monoclonal antibody (Quidel) and immunofluorescence for frozen (F-IF) and a polyclonal antibody (Biomedica) and immunohistochemistry for formalin-fixed and paraffin-embedded (P-IHC) tissue samples. We compared the staining extent (diffuse, focal, minimal, no staining) in frozen and paraffin sections and evaluated the intra- and inter-observer concordance rates using kappa statistics. In addition, we determined the inter-observer concordance in 240 paraffin-embedded biopsies of a multi-centre study.
RESULTS: The inter- and intra-investigator concordance rate (kappa = 0.9) of analysing the C4d expression by F-IF was excellent. In contrast, the detection of C4d by P-IHC demonstrated a substantially lower prevalence and extent of C4d expression with a lower intra- and inter-observer concordance rate (kappa = 0.3). Only 69% of diffuse and 13% of focal C4d-expressing cases were in line classified by F-IF and P-IHC. On average, the estimated area of C4d-positive PTC in the diffuse group was 36% lower by P-IHC than by F-IF. The inter-observer concordance rate in paraffin of the 64 renal biopsies and the multi-centre study was good, but not perfect (kappa = 0.57 or 0.67).
CONCLUSIONS: C4d staining determined on frozen tissue samples using F-IF with a monoclonal antibody appears to be better suited for diagnostic as well as research purposes. Future studies should correlate C4d staining patterns with circulating donor-specific antibodies.

Abstract

BACKGROUND: Detection of C4d along peritubular capillaries (PTC) in renal allograft biopsies is an independent prognostic marker of poor long-term graft survival. It is typically associated with circulating donor-specific antibodies. Since only little information is available on the best technique to stain C4d, we compared the two methods most often used for detecting C4d in renal allograft specimens.
METHODS: We investigated the expression of C4d along PTC in 64 renal allograft biopsies using a monoclonal antibody (Quidel) and immunofluorescence for frozen (F-IF) and a polyclonal antibody (Biomedica) and immunohistochemistry for formalin-fixed and paraffin-embedded (P-IHC) tissue samples. We compared the staining extent (diffuse, focal, minimal, no staining) in frozen and paraffin sections and evaluated the intra- and inter-observer concordance rates using kappa statistics. In addition, we determined the inter-observer concordance in 240 paraffin-embedded biopsies of a multi-centre study.
RESULTS: The inter- and intra-investigator concordance rate (kappa = 0.9) of analysing the C4d expression by F-IF was excellent. In contrast, the detection of C4d by P-IHC demonstrated a substantially lower prevalence and extent of C4d expression with a lower intra- and inter-observer concordance rate (kappa = 0.3). Only 69% of diffuse and 13% of focal C4d-expressing cases were in line classified by F-IF and P-IHC. On average, the estimated area of C4d-positive PTC in the diffuse group was 36% lower by P-IHC than by F-IF. The inter-observer concordance rate in paraffin of the 64 renal biopsies and the multi-centre study was good, but not perfect (kappa = 0.57 or 0.67).
CONCLUSIONS: C4d staining determined on frozen tissue samples using F-IF with a monoclonal antibody appears to be better suited for diagnostic as well as research purposes. Future studies should correlate C4d staining patterns with circulating donor-specific antibodies.

Statistics

Citations

88 citations in Web of Science®
103 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

0 downloads since deposited on 24 Jul 2015
0 downloads since 12 months

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Institute of Pathology and Molecular Pathology
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:February 2007
Deposited On:24 Jul 2015 10:38
Last Modified:05 Apr 2016 19:19
Publisher:Oxford University Press
ISSN:0931-0509
Publisher DOI:https://doi.org/10.1093/ndt/gfl594
PubMed ID:17164320

Download

Preview Icon on Download
Content: Published Version
Filetype: PDF - Registered users only
Size: 377kB
View at publisher

Article Networks

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations