Header

UZH-Logo

Maintenance Infos

Electrocardiographically gated multi-detector row CT for assessment of valvular morphology and calcification in aortic stenosis


Willmann, Jürgen K; Weishaupt, Dominik; Lachat, Mario L; Kobza, Richard; Roos, Justus E; Seifert, Burkhardt; Lüscher, Thomas F; Marincek, Borut; Hilfiker, Paul R (2002). Electrocardiographically gated multi-detector row CT for assessment of valvular morphology and calcification in aortic stenosis. Radiology, 225(1):120-128.

Abstract

PURPOSE To evaluate the applicability and image quality of nonenhanced and contrast material-enhanced multi-detector row computed tomography (CT) combined with retrospective electrocardiographic (ECG) gating for visualization of the aortic valve, determination of aortic valve morphology and diameter of the aortic valve annulus, and assessment of the degree of valvular calcification in patients with aortic valve stenosis, as compared with results of surgery and echocardiography. MATERIALS AND METHODS Prior to surgical valve replacement, 25 patients with aortic valve stenosis and sinus rhythm underwent nonenhanced (n = 15) and contrast-enhanced (n = 25) retrospectively ECG-gated multi-detector row CT. Two readers working in consensus evaluated image quality and assessed valvular morphology and the degree of valvular calcification. In addition, the diameter of the aortic valve annulus was measured. Results were compared with surgical and echocardiographic findings by using the paired sign test, kappa statistics, and the method of Bland and Altman. RESULTS The aortic valve could be visualized nearly free of motion artifacts on all multi-detector row CT images. Image quality and diagnostic confidence for classification of aortic valve morphology were significantly superior on contrast-enhanced rather than nonenhanced images (P =.004 and P =.006, respectively). Nonenhanced and contrast-enhanced CT showed good agreement with surgical findings with regard to quantification of the degree of aortic valve calcification (kappa = 0.77 and kappa = 0.74, respectively). Measurement of the diameter of the aortic valve annulus was more reliable on contrast-enhanced images. CONCLUSION Contrast-enhanced retrospectively ECG-gated multi-detector row CT allows determination of aortic valve morphology, measurement of the diameter of the aortic valve annulus, and assessment of the degree of aortic valve calcification in patients with aortic stenosis.

Abstract

PURPOSE To evaluate the applicability and image quality of nonenhanced and contrast material-enhanced multi-detector row computed tomography (CT) combined with retrospective electrocardiographic (ECG) gating for visualization of the aortic valve, determination of aortic valve morphology and diameter of the aortic valve annulus, and assessment of the degree of valvular calcification in patients with aortic valve stenosis, as compared with results of surgery and echocardiography. MATERIALS AND METHODS Prior to surgical valve replacement, 25 patients with aortic valve stenosis and sinus rhythm underwent nonenhanced (n = 15) and contrast-enhanced (n = 25) retrospectively ECG-gated multi-detector row CT. Two readers working in consensus evaluated image quality and assessed valvular morphology and the degree of valvular calcification. In addition, the diameter of the aortic valve annulus was measured. Results were compared with surgical and echocardiographic findings by using the paired sign test, kappa statistics, and the method of Bland and Altman. RESULTS The aortic valve could be visualized nearly free of motion artifacts on all multi-detector row CT images. Image quality and diagnostic confidence for classification of aortic valve morphology were significantly superior on contrast-enhanced rather than nonenhanced images (P =.004 and P =.006, respectively). Nonenhanced and contrast-enhanced CT showed good agreement with surgical findings with regard to quantification of the degree of aortic valve calcification (kappa = 0.77 and kappa = 0.74, respectively). Measurement of the diameter of the aortic valve annulus was more reliable on contrast-enhanced images. CONCLUSION Contrast-enhanced retrospectively ECG-gated multi-detector row CT allows determination of aortic valve morphology, measurement of the diameter of the aortic valve annulus, and assessment of the degree of aortic valve calcification in patients with aortic stenosis.

Statistics

Citations

127 citations in Web of Science®
147 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Cardiovascular Surgery
04 Faculty of Medicine > Epidemiology, Biostatistics and Prevention Institute (EBPI)
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:October 2002
Deposited On:12 Aug 2015 13:15
Last Modified:08 Dec 2017 13:46
Publisher:Radiological Society of North America
ISSN:0033-8419
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1148/radiol.2251011703
PubMed ID:12354994

Download

Full text not available from this repository.
View at publisher