Nguyên, Uyên Châu; Potse, Mark; Regoli, François; Caputo, Maria Luce; Conte, Giulio; Murzilli, Romina; Muzzarelli, Stefano; Moccetti, Tiziano; Caiani, Enrico G; Prinzen, Frits W; Krause, Rolf; Auricchio, Angelo (2015). An in-silico analysis of the effect of heart position and orientation on the ECG morphology and vectorcardiogram parameters in patients with heart failure and intraventricular conduction defects. Journal of Electrocardiology, 48(4):617-625.

Abstract

AIM The aim of this study was to investigate the influence of geometrical factors on the ECG morphology and vectorcardiogram (VCG) parameters. METHODS Patient-tailored models based on five heart-failure patients with intraventricular conduction defects (IVCDs) were created. The heart was shifted up to 6cm to the left, right, up, and down and rotated ±30° around the anteroposterior axis. Precordial electrodes were shifted 3cm down. RESULTS Geometry modifications strongly altered ECG notching/slurring and intrinsicoid deflection time. Maximum VCG parameter changes were small for QRS duration (-6% to +10%) and QRS-T angle (-6% to +3%), but considerable for QRS amplitude (-36% to +59%), QRS area (-37% to +42%), T-wave amplitude (-41% to +36%), and T-wave area (-42% to +33%). CONCLUSION The position of the heart with respect to the electrodes is an important factor determining notching/slurring and voltage-dependent parameters and therefore must be considered for accurate diagnosis of IVCDs.

Abstract

AIM The aim of this study was to investigate the influence of geometrical factors on the ECG morphology and vectorcardiogram (VCG) parameters. METHODS Patient-tailored models based on five heart-failure patients with intraventricular conduction defects (IVCDs) were created. The heart was shifted up to 6cm to the left, right, up, and down and rotated ±30° around the anteroposterior axis. Precordial electrodes were shifted 3cm down. RESULTS Geometry modifications strongly altered ECG notching/slurring and intrinsicoid deflection time. Maximum VCG parameter changes were small for QRS duration (-6% to +10%) and QRS-T angle (-6% to +3%), but considerable for QRS amplitude (-36% to +59%), QRS area (-37% to +42%), T-wave amplitude (-41% to +36%), and T-wave area (-42% to +33%). CONCLUSION The position of the heart with respect to the electrodes is an important factor determining notching/slurring and voltage-dependent parameters and therefore must be considered for accurate diagnosis of IVCDs.

Statistics

Citations

7 citations in Web of Science®
7 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

2 downloads since deposited on 13 Nov 2015
0 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Cardiocentro Ticino
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2015
Deposited On:13 Nov 2015 09:35
Last Modified:08 Dec 2017 13:50
Publisher:Elsevier
ISSN:0022-0736
Publisher DOI:https://doi.org/10.1016/j.jelectrocard.2015.05.004