Header

UZH-Logo

Maintenance Infos

Comparison of retention forces of different fabrication methods of co-cr crowns: pre-sintered and milled, cast and electroforming secondary crowns with different taper angles


Wagner, Christina; Stock, Veronika; Merk, Susanne; Schmidlin, Patrick R; Roos, Malgorzata; Eichberger, Marlis; Stawarczyk, Bogna (2015). Comparison of retention forces of different fabrication methods of co-cr crowns: pre-sintered and milled, cast and electroforming secondary crowns with different taper angles. International Journal of Dentistry and Oral Science (IJDOS), S2(003):15-20.

Abstract

To investigate the retention forces of differently fabricated secondary crowns made of Co-Cr alloy and electroforming secondary crowns considering different taper angles. Cobalt-chromium primary crowns with 0°, 1° and 2° taper angles were fabricated. Secondary crowns were made either by i) amilling and sintering, ii) castingor iii) electro-forming process. Pull-off tests were performed and data were analyzed by parametric statistics (p<0.05). With regard to the different taper angles, Co-Cr milled and cast groups, no impact on retention force was observed. Within the electroforming group, primary crowns with a taper angle of 1° showed a higher retention force than crowns with angles of 0° or 2°. With respect to the secondary crowns, primary crowns with a taper angle of 1° showed no impact on the results. Within the taper angles of 0° and 2°, the electroforming group exhibited lower retention forces than cast or milled ones. In the 0° taper angle group, milled secondary crowns displayed higher values than cast ones.

Abstract

To investigate the retention forces of differently fabricated secondary crowns made of Co-Cr alloy and electroforming secondary crowns considering different taper angles. Cobalt-chromium primary crowns with 0°, 1° and 2° taper angles were fabricated. Secondary crowns were made either by i) amilling and sintering, ii) castingor iii) electro-forming process. Pull-off tests were performed and data were analyzed by parametric statistics (p<0.05). With regard to the different taper angles, Co-Cr milled and cast groups, no impact on retention force was observed. Within the electroforming group, primary crowns with a taper angle of 1° showed a higher retention force than crowns with angles of 0° or 2°. With respect to the secondary crowns, primary crowns with a taper angle of 1° showed no impact on the results. Within the taper angles of 0° and 2°, the electroforming group exhibited lower retention forces than cast or milled ones. In the 0° taper angle group, milled secondary crowns displayed higher values than cast ones.

Statistics

Altmetrics

Downloads

34 downloads since deposited on 12 Jan 2016
31 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Epidemiology, Biostatistics and Prevention Institute (EBPI)
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2015
Deposited On:12 Jan 2016 10:48
Last Modified:09 Dec 2017 22:35
Publisher:SciDoc Publishers
ISSN:2377-8075
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.19070/2377-8075-SI02003