Radiographic evaluation of immediately loaded implants supporting 2-3 units fixed bridges in the posterior maxilla: a 3-year follow-up prospective randomized controlled multicenter clinical study


Cesaretti, Gianfranco; Botticelli, Daniele; Renzi, Antonio; Rossi, Marcello; Rossi, Riccardo; Lang, Niklaus P (2016). Radiographic evaluation of immediately loaded implants supporting 2-3 units fixed bridges in the posterior maxilla: a 3-year follow-up prospective randomized controlled multicenter clinical study. Clinical Oral Implants Research, 27(4):399-405.

Abstract

OBJECTIVE To compare the survival rate and alveolar bone levels at implants installed in healed sites and functionally loaded within 1 h from installation or after 3 months. MATERIAL AND METHODS A total of 30 patients (17 male and 13 female) were recruited and 71 implants with a SLA(®) surface, 4.1 mm in diameter and 8-12 mm long, were installed in a fully healed alveolar ridge, 36 as test and 35 as control implants. The test implants were immediately loaded with a temporary reconstruction in proper occlusion, while the randomly selected control sites received the final reconstruction after 3 months. Radiographic bone levels were determined after implant installation, prosthesis delivery, and at annual intervals thereafter. RESULTS One patient of the control and one patient of the test were excluded from evaluation. No further losses of implants or patients were seen up to the 3-year follow-up. Hence, data from 28 patients were accounted for. A total of 37 and 36 metal-ceramic crowns were provided at the test and control sites, respectively. No biological and technical complications were observed during the 3-year follow-up. Bone levels at the time of implant installation were at 1.6 ± 0.8 and 1.7 ± 0.9 mm from the implant shoulder at the test and control sites, respectively. At prosthesis delivery, the bone levels were located at 2.4 ± 0.7 mm at the control sites 3 months after implant placement. After 1 year of function, similar bone levels were observed at both sites, displaying 2.4 ± 1.0 and 2.5 ± 0.8 mm at the test and control sites, respectively. No differences were found in the subsequent observation periods. CONCLUSION Survival rates and radiographic bone levels after 1, 2, and 3 years of observation did not differ between conventionally installed implants loaded immediately or delayed (after 3 months). Moreover, insertion torque values did not affect osseointegration.

Abstract

OBJECTIVE To compare the survival rate and alveolar bone levels at implants installed in healed sites and functionally loaded within 1 h from installation or after 3 months. MATERIAL AND METHODS A total of 30 patients (17 male and 13 female) were recruited and 71 implants with a SLA(®) surface, 4.1 mm in diameter and 8-12 mm long, were installed in a fully healed alveolar ridge, 36 as test and 35 as control implants. The test implants were immediately loaded with a temporary reconstruction in proper occlusion, while the randomly selected control sites received the final reconstruction after 3 months. Radiographic bone levels were determined after implant installation, prosthesis delivery, and at annual intervals thereafter. RESULTS One patient of the control and one patient of the test were excluded from evaluation. No further losses of implants or patients were seen up to the 3-year follow-up. Hence, data from 28 patients were accounted for. A total of 37 and 36 metal-ceramic crowns were provided at the test and control sites, respectively. No biological and technical complications were observed during the 3-year follow-up. Bone levels at the time of implant installation were at 1.6 ± 0.8 and 1.7 ± 0.9 mm from the implant shoulder at the test and control sites, respectively. At prosthesis delivery, the bone levels were located at 2.4 ± 0.7 mm at the control sites 3 months after implant placement. After 1 year of function, similar bone levels were observed at both sites, displaying 2.4 ± 1.0 and 2.5 ± 0.8 mm at the test and control sites, respectively. No differences were found in the subsequent observation periods. CONCLUSION Survival rates and radiographic bone levels after 1, 2, and 3 years of observation did not differ between conventionally installed implants loaded immediately or delayed (after 3 months). Moreover, insertion torque values did not affect osseointegration.

Statistics

Citations

2 citations in Web of Science®
2 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

2 downloads since deposited on 22 Jan 2016
0 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Center for Dental Medicine > Clinic for Fixed and Removable Prosthodontics
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2016
Deposited On:22 Jan 2016 09:32
Last Modified:05 Apr 2016 19:58
Publisher:Wiley-Blackwell Publishing, Inc.
ISSN:0905-7161
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1111/clr.12565
PubMed ID:25664701

Download

Preview Icon on Download
Filetype: PDF - Registered users only
Size: 882kB
View at publisher

Article Networks

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations