Surface properties of polyetheretherketone after different laboratory and chairside polishing protocols


Heimer, Sina; Schmidlin, Patrick R; Roos, Malgorzata; Stawarczyk, Bogna (2017). Surface properties of polyetheretherketone after different laboratory and chairside polishing protocols. Journal of Prosthetic Dentistry, 117(3):419-425.

Abstract

STATEMENT OF PROBLEM Polyetheretherketone (PEEK) can be used as a framework material for fixed dental prostheses. However, information about laboratory and chairside polishing methods is still scarce. PURPOSE The purpose of this in vitro study was to determine the effects of laboratory and chairside polishing methods on the surface roughness (SR) and surface free energy (SFE) of PEEK, an autopolymerizing poly(methyl methacrylate), and a veneering composite resin. MATERIAL AND METHODS For each of the 3 materials, 80 specimens were prepared (N=240) and divided into 7 polishing groups and 1 control group (n=10). The 7 groups were split into 4 laboratory protocols: polishing paste (Abraso), a second polishing paste (Opal L), silicone polisher (Ceragum), and diamond grinder (Diagen-Turbo grinder). The other 3 groups were chairside protocols: rainbow technique (Super-Snap kit), polishing paste (Prisma gloss), and a polishing system (Enhance finishing). Machine polishing with SiC P4000 served as the control treatment. The protocols' average SRs and SFEs were measured, and their surface topographies were evaluated with scanning electron microscopy (SEM). The logarithmically transformed data were analyzed using covariance analysis, 2-way and 1-way ANOVA, and partial correlation (α=.05). RESULTS The polishing protocol exerted the highest influence on SR and SFE values (P<.001; SR: partial eta squared ηP(2)=.970; SFE: ηP(2)=.450), followed by material group (P<.001, SR: ηP(2)=.319; SFE: ηP(2)=.429). The interaction effect of the binary combinations of the 2 independent parameters (polishing protocol and material group) was also significant (P<.001, SR: ηP(2)=.681; SFE: ηP(2)=.365). CONCLUSIONS Chairside methods presented lower SR values than laboratory methods, and specimens polished using the 2-body mode showed higher SR than did specimens polished using the 3-body mode.

Abstract

STATEMENT OF PROBLEM Polyetheretherketone (PEEK) can be used as a framework material for fixed dental prostheses. However, information about laboratory and chairside polishing methods is still scarce. PURPOSE The purpose of this in vitro study was to determine the effects of laboratory and chairside polishing methods on the surface roughness (SR) and surface free energy (SFE) of PEEK, an autopolymerizing poly(methyl methacrylate), and a veneering composite resin. MATERIAL AND METHODS For each of the 3 materials, 80 specimens were prepared (N=240) and divided into 7 polishing groups and 1 control group (n=10). The 7 groups were split into 4 laboratory protocols: polishing paste (Abraso), a second polishing paste (Opal L), silicone polisher (Ceragum), and diamond grinder (Diagen-Turbo grinder). The other 3 groups were chairside protocols: rainbow technique (Super-Snap kit), polishing paste (Prisma gloss), and a polishing system (Enhance finishing). Machine polishing with SiC P4000 served as the control treatment. The protocols' average SRs and SFEs were measured, and their surface topographies were evaluated with scanning electron microscopy (SEM). The logarithmically transformed data were analyzed using covariance analysis, 2-way and 1-way ANOVA, and partial correlation (α=.05). RESULTS The polishing protocol exerted the highest influence on SR and SFE values (P<.001; SR: partial eta squared ηP(2)=.970; SFE: ηP(2)=.450), followed by material group (P<.001, SR: ηP(2)=.319; SFE: ηP(2)=.429). The interaction effect of the binary combinations of the 2 independent parameters (polishing protocol and material group) was also significant (P<.001, SR: ηP(2)=.681; SFE: ηP(2)=.365). CONCLUSIONS Chairside methods presented lower SR values than laboratory methods, and specimens polished using the 2-body mode showed higher SR than did specimens polished using the 3-body mode.

Statistics

Altmetrics

Downloads

1 download since deposited on 27 Jan 2017
1 download since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Center for Dental Medicine > Clinic for Preventive Dentistry, Periodontology and Cariology
Dewey Decimal Classification:610 Medicine & health
Date:2017
Deposited On:27 Jan 2017 16:39
Last Modified:07 Mar 2017 02:03
Publisher:Elsevier
ISSN:0022-3913
Publisher DOI:https://doi.org/10.1016/j.prosdent.2016.06.016
PubMed ID:27692577

Download

Preview Icon on Download
Content: Accepted Version
Filetype: PDF - Registered users only until 1 October 2017
Size: 411kB
View at publisher
Embargo till: 2017-10-01

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations