Header

UZH-Logo

Maintenance Infos

Diagnostic accuracy and added value of dual-energy subtraction radiography compared to standard conventional radiography using computed tomography as standard of reference


Martini, Katharina; Baessler, Marco; Baumueller, Stephan; Frauenfelder, Thomas (2017). Diagnostic accuracy and added value of dual-energy subtraction radiography compared to standard conventional radiography using computed tomography as standard of reference. PLoS ONE, 12(3):e0174285.

Abstract

PURPOSE: To retrospectively evaluate diagnostic performance of dual-energy subtraction radiography (DESR) for interpretation of chest radiographs compared to conventional radiography (CR) using computed tomography (CT) as standard of reference.
MATERIAL AND METHODS: A total of 199 patients (75 female, median age 67) were included in this institutional review board (IRB)-approved clinical trial. All patients were scanned in posteroanterior and lateral direction with dual-shot DE-technique. Chest CT was performed within ±72 hours. The system provides three types of images: bone weighted-image, soft tissue weighted-image, herein termed as DESR-images, and a standard image, termed CR-image (marked as CR-image). Images were evaluated by two radiologists for presence of inserted life support lines, pneumothorax, pleural effusion, infectious consolidation, interstitial lung changes, tumor, skeletal alterations, soft tissue alterations, aortic or tracheal calcification and pleural thickening. Inter-observer agreement between readers and diagnostic performance were calculated. McNemar's test was used to test for significant differences.
RESULTS: Mean inter-observer agreement throughout the investigated parameters was higher in DESR images compared to CR-images (kDESR = 0.935 vs. kCR = 0.858). DESR images provided significantly increased sensitivity compared to CR-images for the detection of infectious consolidations (42% vs. 62%), tumor (46% vs. 57%), interstitial lung changes (69% vs. 87%) and aortic or tracheal calcification (25 vs. 73%) (p<0.05). There were no significant differences in sensitivity for the detection of inserted life support lines, pneumothorax, pleural effusion, skeletal alterations, soft tissue alterations or pleural thickening (p>0.05).
CONCLUSION: DESR increases significantly the sensibility without affecting the specificity evaluating chest radiographs, with emphasis on the detection of interstitial lung diseases.

Abstract

PURPOSE: To retrospectively evaluate diagnostic performance of dual-energy subtraction radiography (DESR) for interpretation of chest radiographs compared to conventional radiography (CR) using computed tomography (CT) as standard of reference.
MATERIAL AND METHODS: A total of 199 patients (75 female, median age 67) were included in this institutional review board (IRB)-approved clinical trial. All patients were scanned in posteroanterior and lateral direction with dual-shot DE-technique. Chest CT was performed within ±72 hours. The system provides three types of images: bone weighted-image, soft tissue weighted-image, herein termed as DESR-images, and a standard image, termed CR-image (marked as CR-image). Images were evaluated by two radiologists for presence of inserted life support lines, pneumothorax, pleural effusion, infectious consolidation, interstitial lung changes, tumor, skeletal alterations, soft tissue alterations, aortic or tracheal calcification and pleural thickening. Inter-observer agreement between readers and diagnostic performance were calculated. McNemar's test was used to test for significant differences.
RESULTS: Mean inter-observer agreement throughout the investigated parameters was higher in DESR images compared to CR-images (kDESR = 0.935 vs. kCR = 0.858). DESR images provided significantly increased sensitivity compared to CR-images for the detection of infectious consolidations (42% vs. 62%), tumor (46% vs. 57%), interstitial lung changes (69% vs. 87%) and aortic or tracheal calcification (25 vs. 73%) (p<0.05). There were no significant differences in sensitivity for the detection of inserted life support lines, pneumothorax, pleural effusion, skeletal alterations, soft tissue alterations or pleural thickening (p>0.05).
CONCLUSION: DESR increases significantly the sensibility without affecting the specificity evaluating chest radiographs, with emphasis on the detection of interstitial lung diseases.

Statistics

Citations

Altmetrics

Downloads

13 downloads since deposited on 05 Apr 2017
8 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Diagnostic and Interventional Radiology
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2017
Deposited On:05 Apr 2017 06:50
Last Modified:19 Feb 2018 07:49
Publisher:Public Library of Science (PLoS)
ISSN:1932-6203
OA Status:Gold
Free access at:PubMed ID. An embargo period may apply.
Publisher DOI:https://doi.org/10.1371/journal.pone.0174285
PubMed ID:28301584

Download

Download PDF  'Diagnostic accuracy and added value of dual-energy subtraction radiography compared to standard conventional radiography using computed tomography as standard of reference'.
Preview
Content: Published Version
Filetype: PDF
Size: 1MB
View at publisher
Licence: Creative Commons: Attribution 4.0 International (CC BY 4.0)