A low-dose and an ultra-low-dose contrast agent protocol for coronary CT angiography in a clinical setting: quantitative and qualitative comparison to a standard dose protocol


Benz, Dominik C; Gräni, Christoph; Hirt Moch, Beatrice; Mikulicic, Fran; Vontobel, Jan; Fuchs, Tobias A; Stehli, Julia; Clerc, Olivier F; Possner, Mathias; Pazhenkottil, Aju P; Gaemperli, Oliver; Buechel, Ronny R; Kaufmann, Philipp A (2017). A low-dose and an ultra-low-dose contrast agent protocol for coronary CT angiography in a clinical setting: quantitative and qualitative comparison to a standard dose protocol. British Journal of Radiology, 90(1074):20160933.

Abstract

OBJECTIVES: To evaluate the impact of a low-dose (LD) and an ultra-low-dose (ULD) contrast protocol for coronary computed tomography angiography (CCTA) on qualitative and quantitative image parameters in a clinical setting.
METHODS: We scanned 120 consecutive patients with a 256-slice CT scanner applying a LD (60 patients, 35-55mL) or ULD (60 patients, 25-45mL) contrast protocol adapted to body mass index (BMI). Visually assessed image quality as well as attenuation measured in each coronary segment were retrospectively compared to 20 consecutive patients scanned with a normal-dose (ND, 40-105mL) contrast protocol.
RESULTS: Visually assessed image quality did not differ significantly among protocols. By contrast, attenuation obtained from the ULD protocol (median contrast volume 35ml) differed significantly from the LD (median 45mL) and ND protocol (median 70mL) in coronary segments (316±52HU versus 363±60 HU and 359±52HU, p<0.001). Attenuation did not differ significantly between the LD and ND protocol. The proportion of patients with inadequate coronary vessel attenuation was significantly higher (p<0.001) in the ULD protocol (37%) compared to the ND (5%) and LD (10%) protocol but did not differ significantly between the ND and LD protocol.
CONCLUSION: In a clinical setting, a LD contrast protocol with a median volume of 45mL is feasible for latest-generation 256-slice CCTA as it yields attenuation comparable to a ND protocol. By contrast, the implementation of an ULD protocol remains challenging. Advances in knowledge: Although not perceived by the naked eye, an ultra-low-dose protocol in a clinical setting yields attenuation below a threshold for diagnostic image quality.

Abstract

OBJECTIVES: To evaluate the impact of a low-dose (LD) and an ultra-low-dose (ULD) contrast protocol for coronary computed tomography angiography (CCTA) on qualitative and quantitative image parameters in a clinical setting.
METHODS: We scanned 120 consecutive patients with a 256-slice CT scanner applying a LD (60 patients, 35-55mL) or ULD (60 patients, 25-45mL) contrast protocol adapted to body mass index (BMI). Visually assessed image quality as well as attenuation measured in each coronary segment were retrospectively compared to 20 consecutive patients scanned with a normal-dose (ND, 40-105mL) contrast protocol.
RESULTS: Visually assessed image quality did not differ significantly among protocols. By contrast, attenuation obtained from the ULD protocol (median contrast volume 35ml) differed significantly from the LD (median 45mL) and ND protocol (median 70mL) in coronary segments (316±52HU versus 363±60 HU and 359±52HU, p<0.001). Attenuation did not differ significantly between the LD and ND protocol. The proportion of patients with inadequate coronary vessel attenuation was significantly higher (p<0.001) in the ULD protocol (37%) compared to the ND (5%) and LD (10%) protocol but did not differ significantly between the ND and LD protocol.
CONCLUSION: In a clinical setting, a LD contrast protocol with a median volume of 45mL is feasible for latest-generation 256-slice CCTA as it yields attenuation comparable to a ND protocol. By contrast, the implementation of an ULD protocol remains challenging. Advances in knowledge: Although not perceived by the naked eye, an ultra-low-dose protocol in a clinical setting yields attenuation below a threshold for diagnostic image quality.

Statistics

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Nuclear Medicine
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:13 April 2017
Deposited On:17 May 2017 09:50
Last Modified:07 Jun 2017 01:03
Publisher:British Institute of Radiology
ISSN:0007-1285
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1259/bjr.20160933
PubMed ID:28406318

Download

Full text not available from this repository.
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.