Header

UZH-Logo

Maintenance Infos

Cytokine filtration modulates pulmonary metabolism and edema formation during ex vivo lung perfusion


Iskender, Ilker; Cosgun, Tugba; Arni, Stephan; Trinkwitz, Michael; Fehlings, Stefan; Yamada, Yoshito; Cesarovic, Nikola; Yu, Keke; Frauenfelder, Thomas; Jungraithmayr, Wolfgang; Weder, Walter; Inci, Ilhan (2017). Cytokine filtration modulates pulmonary metabolism and edema formation during ex vivo lung perfusion. Journal of Heart and Lung Transplantation:Epub ahead of print.

Abstract

BACKGROUND: Ex vivo lung perfusion (EVLP) has improved the process of donor lung management. Cytokine accumulation during EVLP has been shown to correlate with worse outcome after lung transplantation. Our objective in this study was to test the safety and efficacy of cytokine filtration during EVLP in a large animal model.
METHODS: Pig donor lungs were preserved for 24 hours at 4°C, followed by 12 hours of EVLP, according to the Toronto protocol. The perfusate was continuously run through an absorbent device (CytoSorb) via a veno-venous shunt from the reservoir in the filter group. EVLP was performed according to the standard protocol in the control group (n = 5 each). EVLP physiology, lung X-ray, perfusate biochemistry, inflammatory response and microscopic injury were assessed.
RESULTS: Cytokine filtration significantly improved airway pressure and dynamic compliance during the 12-hour perfusion period. Lung X-rays acquired at the end of perfusion showed increased consolidation in the control group. Electrolyte imbalance, determined by increased hydrogen, potassium and calcium ion concentrations in the perfusate, was markedly worsened in the control group. Glucose consumption and lactate production were markedly reduced, along with the lactate/pyruvate ratio in the filter group. Cytokine expression profile, tissue myeloperoxidase activity and microscopic lung injury were significantly reduced in the filter group.
CONCLUSIONS: Continuous perfusate filtration through sorbent beads is effective and safe during prolonged EVLP. Cytokine removal decreased the development of pulmonary edema and electrolyte imbalance through the suppression of anaerobic glycolysis and neutrophil activation in this setting. Further studies are needed to test the beneficial effect of cytokine filtration on post-transplant lung function.

Abstract

BACKGROUND: Ex vivo lung perfusion (EVLP) has improved the process of donor lung management. Cytokine accumulation during EVLP has been shown to correlate with worse outcome after lung transplantation. Our objective in this study was to test the safety and efficacy of cytokine filtration during EVLP in a large animal model.
METHODS: Pig donor lungs were preserved for 24 hours at 4°C, followed by 12 hours of EVLP, according to the Toronto protocol. The perfusate was continuously run through an absorbent device (CytoSorb) via a veno-venous shunt from the reservoir in the filter group. EVLP was performed according to the standard protocol in the control group (n = 5 each). EVLP physiology, lung X-ray, perfusate biochemistry, inflammatory response and microscopic injury were assessed.
RESULTS: Cytokine filtration significantly improved airway pressure and dynamic compliance during the 12-hour perfusion period. Lung X-rays acquired at the end of perfusion showed increased consolidation in the control group. Electrolyte imbalance, determined by increased hydrogen, potassium and calcium ion concentrations in the perfusate, was markedly worsened in the control group. Glucose consumption and lactate production were markedly reduced, along with the lactate/pyruvate ratio in the filter group. Cytokine expression profile, tissue myeloperoxidase activity and microscopic lung injury were significantly reduced in the filter group.
CONCLUSIONS: Continuous perfusate filtration through sorbent beads is effective and safe during prolonged EVLP. Cytokine removal decreased the development of pulmonary edema and electrolyte imbalance through the suppression of anaerobic glycolysis and neutrophil activation in this setting. Further studies are needed to test the beneficial effect of cytokine filtration on post-transplant lung function.

Statistics

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Diagnostic and Interventional Radiology
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:20 May 2017
Deposited On:23 Jun 2017 09:51
Last Modified:09 Dec 2017 01:24
Publisher:Elsevier
ISSN:1053-2498
Publisher DOI:https://doi.org/10.1016/j.healun.2017.05.021
PubMed ID:28587802

Download

Full text not available from this repository.
View at publisher