Cardiac Transplantation in a Neonate-First Case in Switzerland and European overview


Schweiger, Martin; Stiasny, Brian; Immer, Franz; Bürki, Christoph; Schmiady, Martin; Dave, Hitendu; Cavigelli-Brunner, Anna; Kretschmar, Oliver; Cannizzaro, Vincenzo; Hübler, Michael (2017). Cardiac Transplantation in a Neonate-First Case in Switzerland and European overview. Clinical Transplantation, 31(5):e12935.

Abstract

Twenty-four percent of pediatric heart transplantations (pHTx) are carried out in infants. Neonatal heart transplantation is both rarely performed and challenging. We report on a newborn baby girl suffering from cardiac failure due to a huge tumor (24×52 mm) within the free wall of the left ventricle (LV) and subtotal obstruction of the main left bronchus. Following a surgical tumor resection, a Berlin Heart EXCOR left ventricular assist device was implanted as the bridge to the transplantation. In spite of an organ donor/recipient mismatch of >200%, both heart transplantation and the postoperative course were successful. In addition to this case report, the authors also present data from a survey on performed infant and neonatal transplantations in Western Europe. As neonatal heart transplantation is a rare event in Europe, the authors think it is of crucial importance to share this limited experience. We discuss an alternative strategy—namely, palliative surgical correction using the Fontan pathway. The challenges of donor/recipient weight mismatch and the possibilities of overcoming infant donor organ shortage as a postoperative immunosuppressive regimen are discussed as well.

Abstract

Twenty-four percent of pediatric heart transplantations (pHTx) are carried out in infants. Neonatal heart transplantation is both rarely performed and challenging. We report on a newborn baby girl suffering from cardiac failure due to a huge tumor (24×52 mm) within the free wall of the left ventricle (LV) and subtotal obstruction of the main left bronchus. Following a surgical tumor resection, a Berlin Heart EXCOR left ventricular assist device was implanted as the bridge to the transplantation. In spite of an organ donor/recipient mismatch of >200%, both heart transplantation and the postoperative course were successful. In addition to this case report, the authors also present data from a survey on performed infant and neonatal transplantations in Western Europe. As neonatal heart transplantation is a rare event in Europe, the authors think it is of crucial importance to share this limited experience. We discuss an alternative strategy—namely, palliative surgical correction using the Fontan pathway. The challenges of donor/recipient weight mismatch and the possibilities of overcoming infant donor organ shortage as a postoperative immunosuppressive regimen are discussed as well.

Statistics

Citations

Altmetrics

Downloads

3 downloads since deposited on 29 Dec 2017
3 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Cardiovascular Surgery
04 Faculty of Medicine > University Children's Hospital Zurich > Medical Clinic
04 Faculty of Medicine > University Children's Hospital Zurich > Clinic for Surgery
Dewey Decimal Classification:610 Medicine & health
Uncontrolled Keywords:Infant heart Transplantation, , Neonate, , Ventricular assist device, , Neonatal donor
Language:English
Date:May 2017
Deposited On:29 Dec 2017 09:14
Last Modified:19 Feb 2018 09:56
Publisher:Wiley-Blackwell Publishing, Inc.
ISSN:0902-0063
OA Status:Closed
Publisher DOI:https://doi.org/10.1111/ctr.12935
PubMed ID:28235145

Download