Autoadjusted versus fixed CPAP for obstructive sleep apnoea: a multicentre, randomised equivalence trial


Bloch, Konrad E; Huber, Fabienne; Furian, Michael; Latshang, Tsogyal D; Lo Cascio, Christian M; Nussbaumer-Ochsner, Yvonne; Senn, Oliver; Russi, Erich W; Kohler, Malcolm; Schoch, Otto D; Turk, Alexander; Imhof, Edelbert; Laube, Irène; Matthews, Felix; Thurnheer, Robert (2018). Autoadjusted versus fixed CPAP for obstructive sleep apnoea: a multicentre, randomised equivalence trial. Thorax, 73(2):174-184.

Abstract

BACKGROUND The obstructive sleep apnoea syndrome (OSAS) is conventionally treated by continuous positive airway pressure set at a fixed level (fCPAP). Automatic mask pressure adjustment (autoCPAP) is increasingly used during home therapy. We investigated whether autoCPAP is equivalent to fCPAP in improving sleepiness in patients with OSAS in the long-term. METHODS In this multicentre equivalence trial, 208 patients with OSAS, with median Epworth sleepiness score (ESS) 13, apnoea/hypopnoea index 48.4/hour, were randomised to treatment with autoCPAP (5-15 mbar) or fCPAP (pressure set at the 90th percentile applied by autoCPAP during 2-4 weeks adaptation). Coprimary outcomes were changes in subjective and objective sleepiness from baseline to 2 years after treatment. Equivalence ranges were ±2 points in ESS and ±3 min sleep resistance time evaluated by recording responses to light signals. RESULTS At 2 years, in the intention to treat analysis, the reduction in sleepiness versus pretreatment baseline was similar in patients using autoCPAP (n=113, mean ESS-change -6.3, 95% CI -7.1 to -5.5; sleep resistance time +8.3 min, +6.9 to +9.7) and fCPAP (n=95, mean ESS-change -6.2, 95% CI -7.0 to -5.3; sleep resistance time +6.3 min, +4.7 to +7.8). The 95% CI of difference in ESS-reduction between autoCPAP and fCPAP was -0.9 to +1.4 and the 95% CI of difference in increase in sleep resistance time was -2.6 to +1.0 min. Blood pressure reduction and OSAS-related costs were similar between groups. CONCLUSIONS AutoCPAP and fCPAP are equivalent within prespecified ranges in improving subjective and objective sleepiness in patients with OSAS over the course of 2 years. Costs of these treatments are similar. TRIAL REGISTRATION NUMBER ClinicalTrials.gov NCT00280800.

Abstract

BACKGROUND The obstructive sleep apnoea syndrome (OSAS) is conventionally treated by continuous positive airway pressure set at a fixed level (fCPAP). Automatic mask pressure adjustment (autoCPAP) is increasingly used during home therapy. We investigated whether autoCPAP is equivalent to fCPAP in improving sleepiness in patients with OSAS in the long-term. METHODS In this multicentre equivalence trial, 208 patients with OSAS, with median Epworth sleepiness score (ESS) 13, apnoea/hypopnoea index 48.4/hour, were randomised to treatment with autoCPAP (5-15 mbar) or fCPAP (pressure set at the 90th percentile applied by autoCPAP during 2-4 weeks adaptation). Coprimary outcomes were changes in subjective and objective sleepiness from baseline to 2 years after treatment. Equivalence ranges were ±2 points in ESS and ±3 min sleep resistance time evaluated by recording responses to light signals. RESULTS At 2 years, in the intention to treat analysis, the reduction in sleepiness versus pretreatment baseline was similar in patients using autoCPAP (n=113, mean ESS-change -6.3, 95% CI -7.1 to -5.5; sleep resistance time +8.3 min, +6.9 to +9.7) and fCPAP (n=95, mean ESS-change -6.2, 95% CI -7.0 to -5.3; sleep resistance time +6.3 min, +4.7 to +7.8). The 95% CI of difference in ESS-reduction between autoCPAP and fCPAP was -0.9 to +1.4 and the 95% CI of difference in increase in sleep resistance time was -2.6 to +1.0 min. Blood pressure reduction and OSAS-related costs were similar between groups. CONCLUSIONS AutoCPAP and fCPAP are equivalent within prespecified ranges in improving subjective and objective sleepiness in patients with OSAS over the course of 2 years. Costs of these treatments are similar. TRIAL REGISTRATION NUMBER ClinicalTrials.gov NCT00280800.

Statistics

Citations

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Pneumology
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:February 2018
Deposited On:23 Jan 2018 13:12
Last Modified:20 Feb 2018 09:03
Publisher:BMJ Publishing Group
ISSN:0040-6376
OA Status:Closed
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1136/thoraxjnl-2016-209699
PubMed ID:28982804

Download

Full text not available from this repository.
View at publisher