Header

UZH-Logo

Maintenance Infos

Mapping of hepatic vascular anatomy: dynamic contrast-enhanced parallel MR imaging compared with 64 detector row CT


Heilmaier, C; Sutter, R; Lutz, A M; Seifert, Burkhardt; Weishaupt, D; Marincek, B; Willmann, J K (2007). Mapping of hepatic vascular anatomy: dynamic contrast-enhanced parallel MR imaging compared with 64 detector row CT. Radiology, 245(3):872-880.

Abstract

The study was approved by the institutional review board, and informed consent was obtained from all patients. The purpose of this study was to retrospectively evaluate the feasibility, reliability, and accuracy of breath-hold dynamic contrast material-enhanced parallel gradient-echo (GRE) magnetic resonance (MR) imaging for mapping the hepatic vascular anatomy, with contrast-enhanced 64-detector row computed tomography (CT) as the reference standard. The parallel GRE MR data sets of 100 patients acquired at 1.5 T were evaluated independently by two blinded readers with respect to (a) image quality for depiction of the hepatic arteries and the portal and hepatic veins and (b) presence of arterial stenosis and variant hepatic vasculature. The readers rated image quality to be good or excellent for 91.1%-100% of the vessels. At parallel GRE MR imaging, the readers diagnosed variant hepatic vessels and arterial stenosis with 94%-100% accuracy. They concluded that parallel GRE MR imaging, as compared with 64-detector row CT, is feasible for hepatic vascular mapping and enables reliable and accurate detection of variant hepatic vasculature and diagnosis of arterial stenosis. Supplemental material: http://radiology.rsnajnls.org/cgi/content/full/2453062103/DC1.

Abstract

The study was approved by the institutional review board, and informed consent was obtained from all patients. The purpose of this study was to retrospectively evaluate the feasibility, reliability, and accuracy of breath-hold dynamic contrast material-enhanced parallel gradient-echo (GRE) magnetic resonance (MR) imaging for mapping the hepatic vascular anatomy, with contrast-enhanced 64-detector row computed tomography (CT) as the reference standard. The parallel GRE MR data sets of 100 patients acquired at 1.5 T were evaluated independently by two blinded readers with respect to (a) image quality for depiction of the hepatic arteries and the portal and hepatic veins and (b) presence of arterial stenosis and variant hepatic vasculature. The readers rated image quality to be good or excellent for 91.1%-100% of the vessels. At parallel GRE MR imaging, the readers diagnosed variant hepatic vessels and arterial stenosis with 94%-100% accuracy. They concluded that parallel GRE MR imaging, as compared with 64-detector row CT, is feasible for hepatic vascular mapping and enables reliable and accurate detection of variant hepatic vasculature and diagnosis of arterial stenosis. Supplemental material: http://radiology.rsnajnls.org/cgi/content/full/2453062103/DC1.

Statistics

Citations

20 citations in Web of Science®
21 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

143 downloads since deposited on 08 Apr 2009
20 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Epidemiology, Biostatistics and Prevention Institute (EBPI)
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2007
Deposited On:08 Apr 2009 14:33
Last Modified:06 Dec 2017 19:24
Publisher:Radiological Society of North America
ISSN:0033-8419
Additional Information:Radiology - Free full text article
Publisher DOI:https://doi.org/10.1148/radiol.2453062103
PubMed ID:17954617

Download

Download PDF  'Mapping of hepatic vascular anatomy: dynamic contrast-enhanced parallel MR imaging compared with 64 detector row CT'.
Preview
Filetype: PDF
Size: 1MB
View at publisher