Header

UZH-Logo

Maintenance Infos

Aortoiliac and lower extremity arteries assessed with 16-detector row CT angiography: prospective comparison with digital subtraction angiography - Zurich Open Repository and Archive


Willmann, J K; Baumert, B; Schertler, T; Wildermuth, S; Pfammatter, T; Verdun, F R; Seifert, Burkhardt; Marincek, B; Böhm, T (2005). Aortoiliac and lower extremity arteries assessed with 16-detector row CT angiography: prospective comparison with digital subtraction angiography. Radiology, 236(3):1083-93.

Abstract

PURPOSE: To prospectively compare the accuracy of 16-detector row computed tomographic (CT) angiography with conventional digital subtraction angiography (DSA) as the reference standard in the assessment of aortoiliac and lower extremity arteries in patients with peripheral arterial disease. MATERIALS AND METHODS: This study was approved by the institutional review board, and informed consent was obtained. A total of 39 consecutive patients (27 men [mean age, 66 years] and 12 women [mean age, 64 years]) with peripheral arterial disease underwent both conventional DSA and 16-detector row CT angiography. For data analysis, the arterial vascular system was divided into 35 segments. A total of 1365 arterial segments were analyzed for arterial stenosis by two independent blinded readers using a four-point grading system (grade 1, <10% luminal narrowing; grade 2, 10%-49% luminal narrowing; grade 3, 50%-99% luminal narrowing; grade 4, occlusion). Interobserver agreements were calculated by using kappa statistics. A third independent blinded reader assessed possible reasons for disagreements between 16-detector row CT angiographic findings and conventional DSA findings. Effective radiation dose was calculated for both imaging modalities. RESULTS: Sixteen-detector row CT angiographic and conventional DSA findings were diagnostic in all vascular segments. Compared with conventional DSA, the sensitivity and specificity of 16-detector row CT angiography with regard to detection of hemodynamically significant stenosis in all 35 arterial segments were 96% and 97%, respectively, for both readers. Readers 1 and 2 overestimated arterial stenosis in 42 (3%) and 34 (2%) arterial segments, respectively, and underestimated arterial stenosis in 13 (1%) and 10 (1%) arterial segments, respectively. Interobserver agreement was excellent (kappa = 0.84-1.00). Presence of anteroposteriorly located luminal narrowing and extensive vascular wall calcification were considered main reasons for disagreements between imaging modalities. Effective radiation dose was lower for 16-detector row CT angiography (1.6-3.9 mSv) than for conventional DSA (6.4-16.0 mSv). CONCLUSION: Sixteen-detector row CT angiography is an accurate and reliable noninvasive alternative to conventional DSA in the assessment of aortoiliac and lower extremity arteries in patients with peripheral arterial disease.

Abstract

PURPOSE: To prospectively compare the accuracy of 16-detector row computed tomographic (CT) angiography with conventional digital subtraction angiography (DSA) as the reference standard in the assessment of aortoiliac and lower extremity arteries in patients with peripheral arterial disease. MATERIALS AND METHODS: This study was approved by the institutional review board, and informed consent was obtained. A total of 39 consecutive patients (27 men [mean age, 66 years] and 12 women [mean age, 64 years]) with peripheral arterial disease underwent both conventional DSA and 16-detector row CT angiography. For data analysis, the arterial vascular system was divided into 35 segments. A total of 1365 arterial segments were analyzed for arterial stenosis by two independent blinded readers using a four-point grading system (grade 1, <10% luminal narrowing; grade 2, 10%-49% luminal narrowing; grade 3, 50%-99% luminal narrowing; grade 4, occlusion). Interobserver agreements were calculated by using kappa statistics. A third independent blinded reader assessed possible reasons for disagreements between 16-detector row CT angiographic findings and conventional DSA findings. Effective radiation dose was calculated for both imaging modalities. RESULTS: Sixteen-detector row CT angiographic and conventional DSA findings were diagnostic in all vascular segments. Compared with conventional DSA, the sensitivity and specificity of 16-detector row CT angiography with regard to detection of hemodynamically significant stenosis in all 35 arterial segments were 96% and 97%, respectively, for both readers. Readers 1 and 2 overestimated arterial stenosis in 42 (3%) and 34 (2%) arterial segments, respectively, and underestimated arterial stenosis in 13 (1%) and 10 (1%) arterial segments, respectively. Interobserver agreement was excellent (kappa = 0.84-1.00). Presence of anteroposteriorly located luminal narrowing and extensive vascular wall calcification were considered main reasons for disagreements between imaging modalities. Effective radiation dose was lower for 16-detector row CT angiography (1.6-3.9 mSv) than for conventional DSA (6.4-16.0 mSv). CONCLUSION: Sixteen-detector row CT angiography is an accurate and reliable noninvasive alternative to conventional DSA in the assessment of aortoiliac and lower extremity arteries in patients with peripheral arterial disease.

Statistics

Citations

118 citations in Web of Science®
158 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

86 downloads since deposited on 09 Jun 2009
15 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Epidemiology, Biostatistics and Prevention Institute (EBPI)
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2005
Deposited On:09 Jun 2009 14:35
Last Modified:05 Apr 2016 13:15
Publisher:Radiological Society of North America
ISSN:0033-8419
Additional Information:Radiology - free full text
Publisher DOI:https://doi.org/10.1148/radiol.2362040895
PubMed ID:16055691

Download

Preview Icon on Download
Preview
Filetype: PDF
Size: 1MB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations