Header

UZH-Logo

Maintenance Infos

Performance studies of the CMS Strip Tracker before installation


Adam, W; et al (2009). Performance studies of the CMS Strip Tracker before installation. Journal of Instrumentation, 4(6):P06009.

Abstract

In March 2007 the assembly of the Silicon Strip Tracker was completed at the Tracker Integration Facility at CERN. Nearly 15% of the detector was instrumented using cables, fiber optics, power supplies, and electronics intended for the operation at the LHC. A local chiller was used to circulate the coolant for low temperature operation. In order to understand the efficiency and alignment of the strip tracker modules, a cosmic ray trigger was implemented. From March through July 4.5 million triggers were recorded. This period, referred to as the Sector Test, provided practical experience with the operation of the Tracker, especially safety, data acquisition, power, and cooling systems. This paper describes the performance of the strip system during the Sector Test, which consisted of five distinct periods defined by the coolant temperature. Significant emphasis is placed on comparisons between the data and results from Monte Carlo studies.

Abstract

In March 2007 the assembly of the Silicon Strip Tracker was completed at the Tracker Integration Facility at CERN. Nearly 15% of the detector was instrumented using cables, fiber optics, power supplies, and electronics intended for the operation at the LHC. A local chiller was used to circulate the coolant for low temperature operation. In order to understand the efficiency and alignment of the strip tracker modules, a cosmic ray trigger was implemented. From March through July 4.5 million triggers were recorded. This period, referred to as the Sector Test, provided practical experience with the operation of the Tracker, especially safety, data acquisition, power, and cooling systems. This paper describes the performance of the strip system during the Sector Test, which consisted of five distinct periods defined by the coolant temperature. Significant emphasis is placed on comparisons between the data and results from Monte Carlo studies.

Statistics

Citations

Dimensions.ai Metrics
6 citations in Web of Science®
10 citations in Scopus®
8 citations in Microsoft Academic
Google Scholar™

Altmetrics

Downloads

114 downloads since deposited on 21 Jan 2010
6 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:07 Faculty of Science > Physics Institute
Dewey Decimal Classification:530 Physics
Language:English
Date:2009
Deposited On:21 Jan 2010 18:51
Last Modified:17 Feb 2018 23:54
Publisher:Institute of Physics Publishing
ISSN:1748-0221
OA Status:Hybrid
Publisher DOI:https://doi.org/10.1088/1748-0221/4/06/P06009

Download

Download PDF  'Performance studies of the CMS Strip Tracker before installation'.
Preview
Filetype: PDF
Size: 4MB
View at publisher