Abstract

BACKGROUND: In modern anthropometry of such complex structures as the face, three-dimensional scanning techniques have become more and more common. Before establishing them as a criterion standard, however, meticulous evaluation of their precision and accuracy under both ideal and clinical circumstances is essential. Potential sources of error need to be identified and addressed. MATERIALS AND METHODS: Under ideal circumstances, a phantom is used to examine the precision and accuracy of the 3dMD system. A clinical setting is simulated by varying different parameters such as angle, distance, and system reregistration, as well as data evaluation under different levels of magnification. RESULTS: The handling of the system was unproblematic in matters of data acquisition and data analysis. It was very reliable, with a mean global error of 0.2 mm (range, 0.1-0.5 mm) for mannequin head measurements. Neither the position of the head nor that of the camera influenced these parameters. New referencing of the system did not influence precision and accuracy. CONCLUSIONS: The precision and accuracy of the tested system are more than sufficient for clinical needs and greater than those of other methods, such as direct anthropometry and two-dimensional photography. The evaluated system can be recommended for evaluation and documentation of the facial surface and could offer new opportunities in reconstructive, orthognathic, and craniofacial surgery.

Abstract

BACKGROUND: In modern anthropometry of such complex structures as the face, three-dimensional scanning techniques have become more and more common. Before establishing them as a criterion standard, however, meticulous evaluation of their precision and accuracy under both ideal and clinical circumstances is essential. Potential sources of error need to be identified and addressed. MATERIALS AND METHODS: Under ideal circumstances, a phantom is used to examine the precision and accuracy of the 3dMD system. A clinical setting is simulated by varying different parameters such as angle, distance, and system reregistration, as well as data evaluation under different levels of magnification. RESULTS: The handling of the system was unproblematic in matters of data acquisition and data analysis. It was very reliable, with a mean global error of 0.2 mm (range, 0.1-0.5 mm) for mannequin head measurements. Neither the position of the head nor that of the camera influenced these parameters. New referencing of the system did not influence precision and accuracy. CONCLUSIONS: The precision and accuracy of the tested system are more than sufficient for clinical needs and greater than those of other methods, such as direct anthropometry and two-dimensional photography. The evaluated system can be recommended for evaluation and documentation of the facial surface and could offer new opportunities in reconstructive, orthognathic, and craniofacial surgery.

Statistics

Citations

Dimensions.ai Metrics
61 citations in Web of Science®
66 citations in Scopus®
61 citations in Microsoft Academic
Google Scholar™

Altmetrics

Downloads

132 downloads since deposited on 15 Jul 2010
30 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Center for Dental Medicine > Clinic for Cranio-Maxillofacial Surgery
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:May 2010
Deposited On:15 Jul 2010 12:50
Last Modified:17 Feb 2018 17:13
Publisher:Lippincott Wiliams & Wilkins
ISSN:1049-2275
Additional Information:This is a non-final version of an article published in final form in Journal of Craniofacial Surgery 2010, 21(3):763-767.
OA Status:Green
Publisher DOI:https://doi.org/10.1097/SCS.0b013e3181d841f7
PubMed ID:20485043

Download

Download PDF  'Precision and accuracy of the 3dMD photogrammetric system in craniomaxillofacial application'.
Preview
Content: Accepted Version
Filetype: PDF
Size: 1MB
View at publisher