Abstract

BACKGROUND: Among the numerous osteotomies for correction of hallux valgus, the modified chevron is known for its good intrinsic stability and the scarf for its large corrective potential. An intermediate design, the reversed-L osteotomy, has been developed to combine these competing biomechanical objectives. The purpose of this in vitro study was to compare the structural and local biomechanical performance of these three designs. METHODS: Stiffness, cortical bone strains (a factor relevant to bone remodeling), strength and failure mode of the scarf, modified chevron and reversed-L osteotomies were measured on human specimens in two different loading configurations. FINDINGS: The scarf osteotomy caused significant changes in stiffness and cortical bone strains with the proximal apex being at the origin of bone failure. The chevron and reversed-L had a generally comparable response to the intact bone. The chevron specimens failed by pivoting of the distal fragment, and the reversed-L by pivoting or fracture. INTERPRETATION: This is the first study to investigate the cortical bone strain changes induced by these invasive osteotomies. Alterations from the intact bone response could be directly related to the design of the osteotomy. Notably, the critical weakening proximal apex of the scarf is avoided in the reversed-L, leading to results comparable to the chevron. This study provides support in favor of the intermediate design of the reversed-L as an effective compromise between the competing biomechanical objectives of corrective potential and mechanical stability.

Abstract

BACKGROUND: Among the numerous osteotomies for correction of hallux valgus, the modified chevron is known for its good intrinsic stability and the scarf for its large corrective potential. An intermediate design, the reversed-L osteotomy, has been developed to combine these competing biomechanical objectives. The purpose of this in vitro study was to compare the structural and local biomechanical performance of these three designs. METHODS: Stiffness, cortical bone strains (a factor relevant to bone remodeling), strength and failure mode of the scarf, modified chevron and reversed-L osteotomies were measured on human specimens in two different loading configurations. FINDINGS: The scarf osteotomy caused significant changes in stiffness and cortical bone strains with the proximal apex being at the origin of bone failure. The chevron and reversed-L had a generally comparable response to the intact bone. The chevron specimens failed by pivoting of the distal fragment, and the reversed-L by pivoting or fracture. INTERPRETATION: This is the first study to investigate the cortical bone strain changes induced by these invasive osteotomies. Alterations from the intact bone response could be directly related to the design of the osteotomy. Notably, the critical weakening proximal apex of the scarf is avoided in the reversed-L, leading to results comparable to the chevron. This study provides support in favor of the intermediate design of the reversed-L as an effective compromise between the competing biomechanical objectives of corrective potential and mechanical stability.

Citations

6 citations in Web of Science®
6 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

497 downloads since deposited on 26 Jul 2010
72 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Balgrist University Hospital, Swiss Spinal Cord Injury Center
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:August 2010
Deposited On:26 Jul 2010 10:03
Last Modified:05 Apr 2016 14:12
Publisher:Elsevier
ISSN:0268-0033
Publisher DOI:https://doi.org/10.1016/j.clinbiomech.2010.05.002
PubMed ID:20621755

Download

Preview Icon on Download
Preview
Content: Accepted Version
Filetype: PDF
Size: 1MB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations