Favre, P; Sussmann, P S; Gerber, C (2010). The effect of component positioning on intrinsic stability of the reverse shoulder arthroplasty. Journal of Shoulder and Elbow Surgery, 19(4):550-556.

Abstract

HYPOTHESIS: Anterior instability is one of the most common complications in reverse shoulder replacement. This study hypothesized that intrinsic stability of a reverse prosthesis varies with the degree of version of the humerus and glenoid components. This should provide guidelines on how to best position the implant components to decrease the rate of dislocation. MATERIALS AND METHODS: Resistance to anterior dislocation of a reverse implant was measured in a mechanical testing machine by means of the stability ratio (ratio of peak dislocation/axial compressive forces). Versions of the humeral and glenoid components were modified in 10 degrees steps in the 90 degrees abducted and resting positions. RESULTS: In both tested positions, the effect of humeral component version was highly significant. Only a glenoid component retroversion of 20 degrees led to a statistically significant drop in stability ratio for the 20 degrees abducted position. Intrinsic stability in the typical component positioning (neutral glenoid version and 20 degrees humeral retroversion) yielded comparably low intrinsic stability, which could only be improved by increasing anteversion of the humeral component. DISCUSSION: Version of the humeral component is the critical factor for intrinsic stability. Version of the glenoid component is less important for intrinsic stability, but special care should be given to avoid retroversions of more than 10 degrees . Within this range, the surgeon can concentrate primarily on other parameters critical for long-term outcome (range of motion, secure fixation) when choosing the appropriate glenoid version. CONCLUSION: Anterior stability can be improved by implanting the humeral component in neutral or with some anteversion.

Abstract

HYPOTHESIS: Anterior instability is one of the most common complications in reverse shoulder replacement. This study hypothesized that intrinsic stability of a reverse prosthesis varies with the degree of version of the humerus and glenoid components. This should provide guidelines on how to best position the implant components to decrease the rate of dislocation. MATERIALS AND METHODS: Resistance to anterior dislocation of a reverse implant was measured in a mechanical testing machine by means of the stability ratio (ratio of peak dislocation/axial compressive forces). Versions of the humeral and glenoid components were modified in 10 degrees steps in the 90 degrees abducted and resting positions. RESULTS: In both tested positions, the effect of humeral component version was highly significant. Only a glenoid component retroversion of 20 degrees led to a statistically significant drop in stability ratio for the 20 degrees abducted position. Intrinsic stability in the typical component positioning (neutral glenoid version and 20 degrees humeral retroversion) yielded comparably low intrinsic stability, which could only be improved by increasing anteversion of the humeral component. DISCUSSION: Version of the humeral component is the critical factor for intrinsic stability. Version of the glenoid component is less important for intrinsic stability, but special care should be given to avoid retroversions of more than 10 degrees . Within this range, the surgeon can concentrate primarily on other parameters critical for long-term outcome (range of motion, secure fixation) when choosing the appropriate glenoid version. CONCLUSION: Anterior stability can be improved by implanting the humeral component in neutral or with some anteversion.

Citations

24 citations in Web of Science®
45 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

104 downloads since deposited on 26 Jul 2010
14 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Balgrist University Hospital, Swiss Spinal Cord Injury Center
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:June 2010
Deposited On:26 Jul 2010 10:03
Last Modified:05 Apr 2016 14:12
Publisher:Elsevier
ISSN:1058-2746
Publisher DOI:https://doi.org/10.1016/j.jse.2009.11.044
PubMed ID:20335055

Download

Preview Icon on Download
Preview
Content: Accepted Version
Filetype: PDF
Size: 1MB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations