High-fidelity device for online recording of foot-stretcher forces during rowing


Krumm, Dominik; Simnacher, Martin; Rauter, Georg; Brunschweiler, Andreas; Odenwald, Stephan; Riener, Robert; Wolf, Peter (2010). High-fidelity device for online recording of foot-stretcher forces during rowing. Procedia Engineering, 2(2):2721-2726.

Abstract

Foot-stretcher forces have been identified as key variables determining rowing performance. The aim of this study was to develop an instrumented foot-stretcher. Under each forefoot, a six degrees of freedom sensor was mounted on an adjustable frame. Under each rearfoot, a one degree of freedom sensor was placed. Validation resulted in an accuracy of vertical forces of about 1% full scale. Sensor’s crosstalk was up to 11% of vertical load. The instrumented foot-stretcher was integrated into a high-level rowing simulator. Propulsive foot-stretcher forces were displayed online and could be used as concurrent feedback about rowing performance

Abstract

Foot-stretcher forces have been identified as key variables determining rowing performance. The aim of this study was to develop an instrumented foot-stretcher. Under each forefoot, a six degrees of freedom sensor was mounted on an adjustable frame. Under each rearfoot, a one degree of freedom sensor was placed. Validation resulted in an accuracy of vertical forces of about 1% full scale. Sensor’s crosstalk was up to 11% of vertical load. The instrumented foot-stretcher was integrated into a high-level rowing simulator. Propulsive foot-stretcher forces were displayed online and could be used as concurrent feedback about rowing performance

Statistics

Citations

1 citation in Web of Science®
1 citation in Scopus®
Google Scholar™

Altmetrics

Downloads

2 downloads since deposited on 31 Jan 2011
2 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Balgrist University Hospital, Swiss Spinal Cord Injury Center
Dewey Decimal Classification:610 Medicine & health
Uncontrolled Keywords:Instrumented foot-stretcher, Engineering design, 3D Kinetics, Concurrent feedback, Rowing simulator
Date:2010
Deposited On:31 Jan 2011 15:27
Last Modified:27 Sep 2017 17:51
Publisher:Elsevier
ISSN:1877-7058
Publisher DOI:https://doi.org/10.1016/j.proeng.2010.04.057