Coronary MR imaging: effect of timing and dose of isosorbide dinitrate administration


Hu, P; Chuang, M L; Ngo, L H; Stoeck, C T; Peters, D C; Kissinger, K V; Goddu, B; Goepfert, L A; Manning, W J; Nezafat, R (2010). Coronary MR imaging: effect of timing and dose of isosorbide dinitrate administration. Radiology, 254(2):401-409.

Abstract

PURPOSE: To quantify the effect of sublingual isosorbide dinitrate (ISDN) administration on coronary magnetic resonance (MR) imaging.

MATERIALS AND METHODS: Written informed consent was obtained from all participants, and the HIPAA-compliant protocol was approved by the Institutional Review Board. Coronary MR imaging was performed at 1.5 T before and after administration of ISDN (2.5 or 5 mg) in 25 healthy adult volunteers (mean age, 23 years +/- 4; nine men, 16 women) with three-dimensional targeted (n = 20, randomized into four groups) or whole-heart (n = 5) acquisitions with gradient-recalled echo (GRE) or balanced steady-state free precession (SSFP) sequences. Image quality was assessed by two cardiologists on a four-point scale. Signal-to-noise ratio (SNR), vessel diameter, and vessel sharpness were characterized. A linear mixed-effects model was used for data analysis. A P value of less than .05 was considered to indicate a significant difference.

RESULTS: The maximum SNR enhancement with 5 mg of ISDN (GRE: 22.0% +/- 10.7%; SSFP: 20.1% +/- 6.0%) was similar (P > .05) to that with 2.5 mg (GRE: 21.9% +/- 5.4%; SSFP: 19.1% +/- 3.0%). However, the time to maximum SNR enhancement for the 5-mg dose (15.5 minutes +/- 6.0) was earlier (P < .01) than that for 2.5 mg (23.5 minutes +/- 6.7). The increase in vessel diameter with 5 mg of ISDN was greater than that with 2.5 mg (P < .05 for both GRE and SSFP sequences). The coronary images were sharper after ISDN administration (P < .03). Subjective image quality score significantly improved after ISDN administration for GRE images (P < .05 for both doses) but was similar for SSFP images (P = .24 for 2.5 mg; P = .27 for 5 mg). Whole-heart coronary SNR was improved about 10% after ISDN administration (P < .05).

CONCLUSION: Sublingual ISDN improves coronary MR imaging SNR. Practitioners need to consider the dose and temporal effects of ISDN when performing coronary MR imaging.

Abstract

PURPOSE: To quantify the effect of sublingual isosorbide dinitrate (ISDN) administration on coronary magnetic resonance (MR) imaging.

MATERIALS AND METHODS: Written informed consent was obtained from all participants, and the HIPAA-compliant protocol was approved by the Institutional Review Board. Coronary MR imaging was performed at 1.5 T before and after administration of ISDN (2.5 or 5 mg) in 25 healthy adult volunteers (mean age, 23 years +/- 4; nine men, 16 women) with three-dimensional targeted (n = 20, randomized into four groups) or whole-heart (n = 5) acquisitions with gradient-recalled echo (GRE) or balanced steady-state free precession (SSFP) sequences. Image quality was assessed by two cardiologists on a four-point scale. Signal-to-noise ratio (SNR), vessel diameter, and vessel sharpness were characterized. A linear mixed-effects model was used for data analysis. A P value of less than .05 was considered to indicate a significant difference.

RESULTS: The maximum SNR enhancement with 5 mg of ISDN (GRE: 22.0% +/- 10.7%; SSFP: 20.1% +/- 6.0%) was similar (P > .05) to that with 2.5 mg (GRE: 21.9% +/- 5.4%; SSFP: 19.1% +/- 3.0%). However, the time to maximum SNR enhancement for the 5-mg dose (15.5 minutes +/- 6.0) was earlier (P < .01) than that for 2.5 mg (23.5 minutes +/- 6.7). The increase in vessel diameter with 5 mg of ISDN was greater than that with 2.5 mg (P < .05 for both GRE and SSFP sequences). The coronary images were sharper after ISDN administration (P < .03). Subjective image quality score significantly improved after ISDN administration for GRE images (P < .05 for both doses) but was similar for SSFP images (P = .24 for 2.5 mg; P = .27 for 5 mg). Whole-heart coronary SNR was improved about 10% after ISDN administration (P < .05).

CONCLUSION: Sublingual ISDN improves coronary MR imaging SNR. Practitioners need to consider the dose and temporal effects of ISDN when performing coronary MR imaging.

Statistics

Citations

11 citations in Web of Science®
12 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

72 downloads since deposited on 10 Feb 2011
13 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Institute of Biomedical Engineering
Dewey Decimal Classification:170 Ethics
610 Medicine & health
Language:English
Date:2010
Deposited On:10 Feb 2011 14:21
Last Modified:20 Aug 2017 23:54
Publisher:Radiological Society of North America
ISSN:0033-8419
Free access at:PubMed ID. An embargo period may apply.
Publisher DOI:https://doi.org/10.1148/radiol.09090483
PubMed ID:20093512

Download

Download PDF  'Coronary MR imaging: effect of timing and dose of isosorbide dinitrate administration'.
Preview
Filetype: PDF
Size: 1MB
View at publisher