How does sacral modulation work best? Placement and programming techniques to maximize efficacy


Amend, B; Khalil, M; Kessler, T M; Sievert, K D (2011). How does sacral modulation work best? Placement and programming techniques to maximize efficacy. Current Urology Reports, 12(5):327-335.

Abstract

Since receiving approval from the US Food and Drug Administration in 1997, sacral neuromodulation (SNM) has become the recommended treatment of urinary urge incontinence, urgency-frequency, nonobstructive urinary retention, and fecal incontinence. The manufacturer has introduced different technical modifications while surgeons and researchers have adapted and published various innovations and alterations of the technique. This review summarizes the current knowledge and recommendations of SNM preoperative decision making, the implantation technique, and available programming parameters and algorithms based on MEDLINE research, manufacturer instructions, and the approach of an experienced neurourological team. The primary steps and technical aspects to optimize SNM efficacy were the introduction of the tined-lead electrode and the development of the InterStim II impulse generator (both developed by Medtronic, Inc., Minneapolis, MN). The initiation of the staged implantation technique for sequential evaluation and implantation with the definitive quadripolar electrode completes the treatment algorithm so that an increased responder rate of SNM for all indications can be achieved.

Abstract

Since receiving approval from the US Food and Drug Administration in 1997, sacral neuromodulation (SNM) has become the recommended treatment of urinary urge incontinence, urgency-frequency, nonobstructive urinary retention, and fecal incontinence. The manufacturer has introduced different technical modifications while surgeons and researchers have adapted and published various innovations and alterations of the technique. This review summarizes the current knowledge and recommendations of SNM preoperative decision making, the implantation technique, and available programming parameters and algorithms based on MEDLINE research, manufacturer instructions, and the approach of an experienced neurourological team. The primary steps and technical aspects to optimize SNM efficacy were the introduction of the tined-lead electrode and the development of the InterStim II impulse generator (both developed by Medtronic, Inc., Minneapolis, MN). The initiation of the staged implantation technique for sequential evaluation and implantation with the definitive quadripolar electrode completes the treatment algorithm so that an increased responder rate of SNM for all indications can be achieved.

Statistics

Citations

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Balgrist University Hospital, Swiss Spinal Cord Injury Center
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:October 2011
Deposited On:21 Feb 2012 16:04
Last Modified:07 Dec 2017 12:51
Publisher:Springer
ISSN:1527-2737
Publisher DOI:https://doi.org/10.1007/s11934-011-0204-2
PubMed ID:21710239

Download

Full text not available from this repository.
View at publisher