Header

UZH-Logo

Maintenance Infos

In-plane motions of the stapes in human ears


Lauxmann, M; Eiber, A; Heckeler, C; Ihrle, S; Chatzimichalis, M; Huber, A; Sim, J H (2012). In-plane motions of the stapes in human ears. Journal of the Acoustical Society of America, 132(5):3280-91.

Abstract

The piston-like (translation normal to the footplate) and rocking-like (rotation along the long and short axes of the footplate) are generally accepted as motion components of the human stapes. It has been of issue whether in-plane motions, i.e., transversal movements of the footplate in the oval window, are comparable to these motion components. In order to quantify the in-plane motions the motion at nine points on the medial footplate was measured in five temporal bones with the cochlea drained using a three-dimensional (3D) laser Doppler vibrometer. It was found that the stapes shows in-plane movements up to 19.1 ± 8.7% of the piston-like motion. By considering possible methodological errors, i.e., the effects of the applied reflective glass beads and of alignment of the 3D laser Doppler system, such value was reduced to be about 7.4 ± 3.1%. Further, the in-plane motions became minimal ( ≈ 4.2 ± 1.4% of the piston-like motion) in another plane, which was anatomically within the footplate. That plane was shifted to the lateral direction by 118 μm, which was near the middle of the footplate, and rotated by 4.7° with respect to the medial footplate plane.

Abstract

The piston-like (translation normal to the footplate) and rocking-like (rotation along the long and short axes of the footplate) are generally accepted as motion components of the human stapes. It has been of issue whether in-plane motions, i.e., transversal movements of the footplate in the oval window, are comparable to these motion components. In order to quantify the in-plane motions the motion at nine points on the medial footplate was measured in five temporal bones with the cochlea drained using a three-dimensional (3D) laser Doppler vibrometer. It was found that the stapes shows in-plane movements up to 19.1 ± 8.7% of the piston-like motion. By considering possible methodological errors, i.e., the effects of the applied reflective glass beads and of alignment of the 3D laser Doppler system, such value was reduced to be about 7.4 ± 3.1%. Further, the in-plane motions became minimal ( ≈ 4.2 ± 1.4% of the piston-like motion) in another plane, which was anatomically within the footplate. That plane was shifted to the lateral direction by 118 μm, which was near the middle of the footplate, and rotated by 4.7° with respect to the medial footplate plane.

Statistics

Citations

Dimensions.ai Metrics
7 citations in Web of Science®
6 citations in Scopus®
7 citations in Microsoft Academic
Google Scholar™

Altmetrics

Downloads

13 downloads since deposited on 19 Dec 2012
6 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Otorhinolaryngology
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:November 2012
Deposited On:19 Dec 2012 13:51
Last Modified:17 Feb 2018 00:28
Publisher:American Institute of Physics
ISSN:0001-4966
OA Status:Green
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1121/1.4756925
PubMed ID:23145612

Download

Download PDF  'In-plane motions of the stapes in human ears'.
Preview
Content: Published Version
Filetype: PDF
Size: 3MB