Metal artefact reduction from dental hardware in carotid CT angiography using iterative reconstructions


Morsbach, Fabian; Wurnig, Moritz; Kunz, Daniel M; Krauss, Andreas; Schmidt, Bernhard; Kollias, Spyros S; Alkadhi, Hatem (2013). Metal artefact reduction from dental hardware in carotid CT angiography using iterative reconstructions. European Radiology, 23(10):2687-2694.

Abstract

PURPOSE: To determine the value of a metal artefact reduction (MAR) algorithm with iterative reconstructions for dental hardware in carotid CT angiography. METHODS: Twenty-four patients (six of which were women; mean age 70 ± 12 years) with dental hardware undergoing carotid CT angiography were included. Datasets were reconstructed with filtered back projection (FBP) and using a MAR algorithm employing normalisation and an iterative frequency-split (IFS) approach. Three blinded, independent readers measured CT attenuation values and evaluated image quality and degrees of artefacts using axial images, multi-planar reformations (MPRs) and maximal intensity projections (MIP) of the carotid arteries. RESULTS: CT attenuation values of the internal carotid artery on images with metal artefacts were significantly higher in FBP (324 ± 104HU) datasets compared with those reconstructed with IFS (278 ± 114HU; P < 0.001) and with FBP on images without metal artefacts (293 ± 106HU; P = 0.006). Quality of IFS images was rated significantly higher on axial, MPR and MIP images (P < 0.05, each), and readers found significantly less artefacts impairing the diagnostic confidence of the internal carotid artery (P < 0.05, each). CONCLUSION: The MAR algorithm with the IFS approach allowed for a significant reduction of artefacts from dental hardware in carotid CT angiography, hereby increasing image quality and improving the accuracy of CT attenuation measurements. KEY POINTS: • CT angiography of the neck has proven value for evaluating carotid disease • Neck CT angiography images are often degraded by artefacts from dental implants • A metal artefact reduction algorithm with iterative reconstruction reduces artefacts significantly • Visualisation of the internal carotid artery is improved.

Abstract

PURPOSE: To determine the value of a metal artefact reduction (MAR) algorithm with iterative reconstructions for dental hardware in carotid CT angiography. METHODS: Twenty-four patients (six of which were women; mean age 70 ± 12 years) with dental hardware undergoing carotid CT angiography were included. Datasets were reconstructed with filtered back projection (FBP) and using a MAR algorithm employing normalisation and an iterative frequency-split (IFS) approach. Three blinded, independent readers measured CT attenuation values and evaluated image quality and degrees of artefacts using axial images, multi-planar reformations (MPRs) and maximal intensity projections (MIP) of the carotid arteries. RESULTS: CT attenuation values of the internal carotid artery on images with metal artefacts were significantly higher in FBP (324 ± 104HU) datasets compared with those reconstructed with IFS (278 ± 114HU; P < 0.001) and with FBP on images without metal artefacts (293 ± 106HU; P = 0.006). Quality of IFS images was rated significantly higher on axial, MPR and MIP images (P < 0.05, each), and readers found significantly less artefacts impairing the diagnostic confidence of the internal carotid artery (P < 0.05, each). CONCLUSION: The MAR algorithm with the IFS approach allowed for a significant reduction of artefacts from dental hardware in carotid CT angiography, hereby increasing image quality and improving the accuracy of CT attenuation measurements. KEY POINTS: • CT angiography of the neck has proven value for evaluating carotid disease • Neck CT angiography images are often degraded by artefacts from dental implants • A metal artefact reduction algorithm with iterative reconstruction reduces artefacts significantly • Visualisation of the internal carotid artery is improved.

Statistics

Citations

27 citations in Web of Science®
29 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Diagnostic and Interventional Radiology
04 Faculty of Medicine > University Hospital Zurich > Clinic for Neuroradiology
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2013
Deposited On:23 May 2013 13:18
Last Modified:07 Dec 2017 21:13
Publisher:Springer
ISSN:0938-7994
Publisher DOI:https://doi.org/10.1007/s00330-013-2885-z
PubMed ID:23686292

Download

Full text not available from this repository.
View at publisher