Medicolegal X-Ray and CT of standard size mobile phone cards (SIM card)


Schweitzer, Wolf; Winklhofer, Sebastian; Thali, Michael J; Adura Yaakup, Nur; Nizam bin Abdul Rashid, Saiful (2013). Medicolegal X-Ray and CT of standard size mobile phone cards (SIM card). Journal of Forensic Radiology and Imaging, 1(3):129-133.

Abstract

Background. Foreign body ingestion typically affects children or adults with mental conditions. SIM (subscriber identity module) card ingestion is extremely rare. As their particularly X-Ray dense metal parts are sized about View the MathML source9×12mm×50−−80μ, they can be difficult to capture on plain radiographs. We were asked by investigative authorities to point out the best method to document intentionally swallowed SIM cards. Method and material. A case of a 23 year old female who had swallowed a SIM card when she was arrested for murder was followed up with four abdomen radiographs and CT (computed tomography) of the abdomen. Experimentally, SIM cards were examined in CT. SIM card object contrast against surrounding background was quantified through CNR (contrast-to-noise ratio). Results. SIM card orientation perpendicular to plain film X-Ray beams resulted in relatively low CNR values of 1.6–2.5. SIM cards in CT scans yielded considerably better CNR values exceeding 9. Discussion. While plain abdomen radiographs have a lower X-Ray dose than abdomen CT scans, more frequent possibly negative results may lead to repetitive exposure. We recommend to consider drug trafficking as possible problem in conjunction with any observed SIM card swallowing, particularly in context of police arrests or a suspect's detention. We recommend to consider CT of the abdomen, if possible with a low dose, rather than plain abdomen radiographs.

Abstract

Background. Foreign body ingestion typically affects children or adults with mental conditions. SIM (subscriber identity module) card ingestion is extremely rare. As their particularly X-Ray dense metal parts are sized about View the MathML source9×12mm×50−−80μ, they can be difficult to capture on plain radiographs. We were asked by investigative authorities to point out the best method to document intentionally swallowed SIM cards. Method and material. A case of a 23 year old female who had swallowed a SIM card when she was arrested for murder was followed up with four abdomen radiographs and CT (computed tomography) of the abdomen. Experimentally, SIM cards were examined in CT. SIM card object contrast against surrounding background was quantified through CNR (contrast-to-noise ratio). Results. SIM card orientation perpendicular to plain film X-Ray beams resulted in relatively low CNR values of 1.6–2.5. SIM cards in CT scans yielded considerably better CNR values exceeding 9. Discussion. While plain abdomen radiographs have a lower X-Ray dose than abdomen CT scans, more frequent possibly negative results may lead to repetitive exposure. We recommend to consider drug trafficking as possible problem in conjunction with any observed SIM card swallowing, particularly in context of police arrests or a suspect's detention. We recommend to consider CT of the abdomen, if possible with a low dose, rather than plain abdomen radiographs.

Statistics

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Diagnostic and Interventional Radiology
04 Faculty of Medicine > Institute of Legal Medicine
Dewey Decimal Classification:340 Law
610 Medicine & health
Language:English
Date:2013
Deposited On:16 Jul 2013 09:06
Last Modified:05 Apr 2016 16:52
Publisher:Elsevier
ISSN:2212-4780
Publisher DOI:https://doi.org/10.1016/j.jofri.2013.05.004

Download

Full text not available from this repository.
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations