Schmuziger, N; Patscheke, J; Probst, R (2006). Automated pure-tone threshold estimations from extrapolated distortion product otoacoustic emission (DPOAE) input/output functions. Journal of the Acoustical Society of America, 119(4):1937-1939.

Abstract

A promising approach to the prediction of pure-tone thresholds through the estimation of DPOAE thresholds by input/output functions was recently published by Boege and Janssen [J. Acoust. Soc. Am. 111, 1810-1818 (2002)]. On the basis of their results, a device that enables automated measurements of these thresholds was recently developed. The purpose of the current study was to evaluate the reliability of this instrument for the objective assessment of hearing loss in 101 ears with either normal hearing or with cochlear hearing loss of up to 50 dB HL. The median difference between pure-tone hearing and DPOAE thresholds was approximately 2 dB. For individual subjects, however, DPOAE thresholds differed from pure-tone thresholds by up to 40 dB. We find, therefore, that the clinical benefits of this method are probably limited.

Abstract

A promising approach to the prediction of pure-tone thresholds through the estimation of DPOAE thresholds by input/output functions was recently published by Boege and Janssen [J. Acoust. Soc. Am. 111, 1810-1818 (2002)]. On the basis of their results, a device that enables automated measurements of these thresholds was recently developed. The purpose of the current study was to evaluate the reliability of this instrument for the objective assessment of hearing loss in 101 ears with either normal hearing or with cochlear hearing loss of up to 50 dB HL. The median difference between pure-tone hearing and DPOAE thresholds was approximately 2 dB. For individual subjects, however, DPOAE thresholds differed from pure-tone thresholds by up to 40 dB. We find, therefore, that the clinical benefits of this method are probably limited.

Citations

9 citations in Web of Science®
8 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Otorhinolaryngology
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2006
Deposited On:30 Mar 2009 10:18
Last Modified:05 Apr 2016 12:43
Publisher:Acoustical Society of America
ISSN:0001-4966
Publisher DOI:https://doi.org/10.1121/1.2180531
PubMed ID:16642804

Download

Full text not available from this repository.
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations