Header

UZH-Logo

Maintenance Infos

3D analysis of the proximal interphalangeal joint kinematics during flexion


Hess, Florian; Fürnstahl, Philipp; Gallo, Luigi-Maria; Schweizer, Andreas (2013). 3D analysis of the proximal interphalangeal joint kinematics during flexion. Computational and Mathematical Methods in Medicine, 2013:138063.

Abstract

Background. Dynamic joint motion recording combined with CT-based 3D bone and joint surface data is accepted as a helpful and precise tool to analyse joint. The purpose of this study is to demonstrate the feasibility of these techniques for quantitative motion analysis of the interphalangeal joint in 3D. Materials and Method. High resolution motion data was combined with an accurate 3D model of a cadaveric index finger. Three light-emitting diodes (LEDs) were used to record dynamic data, and a CT scan of the finger was done for 3D joint surface geometry. The data allowed performing quantitative evaluations such as finite helical axis (FHA) analysis, coordinate system optimization, and measurement of the joint distances in 3D. Results. The FHA varies by 4.9 ± 1.7° on average. On average, the rotation in adduction/abduction and internal/external rotation were 0.3 ± 0.91° and 0.1 ± 0.97°, respectively. During flexion, a translational motion between 0.06 mm and 0.73 mm was observed. Conclusions. The proposed technique and methods appear to be feasible for the accurate assessment and evaluation of the PIP joint motion in 3D. The presented method may help to gain additional insights for the design of prosthetic implants, rehabilitation, and new orthotic devices.

Abstract

Background. Dynamic joint motion recording combined with CT-based 3D bone and joint surface data is accepted as a helpful and precise tool to analyse joint. The purpose of this study is to demonstrate the feasibility of these techniques for quantitative motion analysis of the interphalangeal joint in 3D. Materials and Method. High resolution motion data was combined with an accurate 3D model of a cadaveric index finger. Three light-emitting diodes (LEDs) were used to record dynamic data, and a CT scan of the finger was done for 3D joint surface geometry. The data allowed performing quantitative evaluations such as finite helical axis (FHA) analysis, coordinate system optimization, and measurement of the joint distances in 3D. Results. The FHA varies by 4.9 ± 1.7° on average. On average, the rotation in adduction/abduction and internal/external rotation were 0.3 ± 0.91° and 0.1 ± 0.97°, respectively. During flexion, a translational motion between 0.06 mm and 0.73 mm was observed. Conclusions. The proposed technique and methods appear to be feasible for the accurate assessment and evaluation of the PIP joint motion in 3D. The presented method may help to gain additional insights for the design of prosthetic implants, rehabilitation, and new orthotic devices.

Statistics

Citations

Dimensions.ai Metrics
1 citation in Web of Science®
5 citations in Scopus®
4 citations in Microsoft Academic
Google Scholar™

Altmetrics

Downloads

65 downloads since deposited on 16 Dec 2013
18 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Balgrist University Hospital, Swiss Spinal Cord Injury Center
04 Faculty of Medicine > Center for Dental Medicine > Clinic for Masticatory Disorders
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2013
Deposited On:16 Dec 2013 13:42
Last Modified:16 Feb 2018 18:33
Publisher:Hindawi Publishing Corporation
ISSN:1748-670X
OA Status:Gold
Free access at:PubMed ID. An embargo period may apply.
Publisher DOI:https://doi.org/10.1155/2013/138063
PubMed ID:24302972

Download

Download PDF  '3D analysis of the proximal interphalangeal joint kinematics during flexion'.
Preview
Content: Published Version
Filetype: PDF
Size: 2MB
View at publisher