3D analysis of the proximal interphalangeal joint kinematics during flexion


Hess, Florian; Fürnstahl, Philipp; Gallo, Luigi-Maria; Schweizer, Andreas (2013). 3D analysis of the proximal interphalangeal joint kinematics during flexion. Computational and Mathematical Methods in Medicine, 2013:138063.

Abstract

Background. Dynamic joint motion recording combined with CT-based 3D bone and joint surface data is accepted as a helpful and precise tool to analyse joint. The purpose of this study is to demonstrate the feasibility of these techniques for quantitative motion analysis of the interphalangeal joint in 3D. Materials and Method. High resolution motion data was combined with an accurate 3D model of a cadaveric index finger. Three light-emitting diodes (LEDs) were used to record dynamic data, and a CT scan of the finger was done for 3D joint surface geometry. The data allowed performing quantitative evaluations such as finite helical axis (FHA) analysis, coordinate system optimization, and measurement of the joint distances in 3D. Results. The FHA varies by 4.9 ± 1.7° on average. On average, the rotation in adduction/abduction and internal/external rotation were 0.3 ± 0.91° and 0.1 ± 0.97°, respectively. During flexion, a translational motion between 0.06 mm and 0.73 mm was observed. Conclusions. The proposed technique and methods appear to be feasible for the accurate assessment and evaluation of the PIP joint motion in 3D. The presented method may help to gain additional insights for the design of prosthetic implants, rehabilitation, and new orthotic devices.

Abstract

Background. Dynamic joint motion recording combined with CT-based 3D bone and joint surface data is accepted as a helpful and precise tool to analyse joint. The purpose of this study is to demonstrate the feasibility of these techniques for quantitative motion analysis of the interphalangeal joint in 3D. Materials and Method. High resolution motion data was combined with an accurate 3D model of a cadaveric index finger. Three light-emitting diodes (LEDs) were used to record dynamic data, and a CT scan of the finger was done for 3D joint surface geometry. The data allowed performing quantitative evaluations such as finite helical axis (FHA) analysis, coordinate system optimization, and measurement of the joint distances in 3D. Results. The FHA varies by 4.9 ± 1.7° on average. On average, the rotation in adduction/abduction and internal/external rotation were 0.3 ± 0.91° and 0.1 ± 0.97°, respectively. During flexion, a translational motion between 0.06 mm and 0.73 mm was observed. Conclusions. The proposed technique and methods appear to be feasible for the accurate assessment and evaluation of the PIP joint motion in 3D. The presented method may help to gain additional insights for the design of prosthetic implants, rehabilitation, and new orthotic devices.

Statistics

Altmetrics

Downloads

48 downloads since deposited on 16 Dec 2013
11 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Balgrist University Hospital, Swiss Spinal Cord Injury Center
04 Faculty of Medicine > Center for Dental Medicine > Clinic for Masticatory Disorders and Complete Dentures, Geriatric and Special Care Dentistry
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2013
Deposited On:16 Dec 2013 13:42
Last Modified:07 Aug 2017 03:01
Publisher:Hindawi Publishing Corporation
ISSN:1748-670X
Free access at:PubMed ID. An embargo period may apply.
Publisher DOI:https://doi.org/10.1155/2013/138063
PubMed ID:24302972

Download

Preview Icon on Download
Preview
Content: Published Version
Filetype: PDF
Size: 2MB
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.
You can navigate and zoom the map. Mouse-hovering a term displays its timeline, clicking it yields the associated documents.

Author Collaborations