Biomechanical comparison of different external fixation configurations for posttraumatic pelvic ring instability


Tiziani, Simon; Osterhoff, Georg; Ferguson, Stephen J; Spreiter, Gregor; Scheyerer, Max J; Spinas, Gian-Leza; Wanner, Guido A; Simmen, Hans-Peter; Werner, Clément M L (2014). Biomechanical comparison of different external fixation configurations for posttraumatic pelvic ring instability. Advances in Orthopedic Surgery, 2014:360165.

Abstract

Background. External fixation is useful in the primary treatment of pelvic ring injuries. The present study compared the biomechanical stability of five different configurations of an external pelvic ring fixation system. Methods. Five configurations of an anterior external pelvic ring fixation system were tested using a universal testing machine. One single connecting rod was used in group “SINGLE,” two parallel connecting rods in group “DOUBLE,” two and four rods, respectively, in a tent-like configuration in groups “SINGLE TENT” and “DOUBLE TENT,” and a rhomboid-like configuration in group “RHOMBOID.” Each specimen was subjected to a total of 2000 consecutive cyclic loadings at 1 Hz lateral compression/distraction (±50 N) and torque (±0.5 Nm) loading alternating every 200 cycles. Translational and rotational stiffness were determined at 100, 300, 500, 700, and 900 cycles. Results. The “SINGLE TENT” and “RHOMBOID” configurations already failed with a preloading of 50 N compression force. The “DOUBLE” configuration had around twice the translational stability compared with the “SINGLE” and “DOUBLE TENT” configurations. Rotational stiffness observed for the “DOUBLE” and “DOUBLE TENT” configurations was about 50% higher compared to the SINGLE configuration. Conclusion. Using two parallel connecting rods provides the highest translational and rotational stability.

Abstract

Background. External fixation is useful in the primary treatment of pelvic ring injuries. The present study compared the biomechanical stability of five different configurations of an external pelvic ring fixation system. Methods. Five configurations of an anterior external pelvic ring fixation system were tested using a universal testing machine. One single connecting rod was used in group “SINGLE,” two parallel connecting rods in group “DOUBLE,” two and four rods, respectively, in a tent-like configuration in groups “SINGLE TENT” and “DOUBLE TENT,” and a rhomboid-like configuration in group “RHOMBOID.” Each specimen was subjected to a total of 2000 consecutive cyclic loadings at 1 Hz lateral compression/distraction (±50 N) and torque (±0.5 Nm) loading alternating every 200 cycles. Translational and rotational stiffness were determined at 100, 300, 500, 700, and 900 cycles. Results. The “SINGLE TENT” and “RHOMBOID” configurations already failed with a preloading of 50 N compression force. The “DOUBLE” configuration had around twice the translational stability compared with the “SINGLE” and “DOUBLE TENT” configurations. Rotational stiffness observed for the “DOUBLE” and “DOUBLE TENT” configurations was about 50% higher compared to the SINGLE configuration. Conclusion. Using two parallel connecting rods provides the highest translational and rotational stability.

Statistics

Altmetrics

Downloads

103 downloads since deposited on 17 Jan 2014
27 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Trauma Surgery
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2014
Deposited On:17 Jan 2014 07:38
Last Modified:07 Sep 2017 17:20
Publisher:Hindawi
ISSN:2314-8233
Publisher DOI:https://doi.org/10.1155/2014/360165
Official URL:http://www.hindawi.com/journals/aos/aip/360165/

Download

Download PDF  'Biomechanical comparison of different external fixation configurations for posttraumatic pelvic ring instability'.
Preview
Content: Accepted Version
Filetype: PDF
Size: 727kB
View at publisher
Download PDF  'Biomechanical comparison of different external fixation configurations for posttraumatic pelvic ring instability'.
Preview
Content: Published Version
Language: English
Filetype: PDF
Size: 2MB
Licence: Creative Commons: Attribution 3.0 Unported (CC BY 3.0)