Simultaneous replacement of maxillary central incisors with Cerec biogeneric reference technique: A case report


Akgungor, Gokhan; Sen, Deniz; Bal, Eray; Özcan, Mutlu (2013). Simultaneous replacement of maxillary central incisors with Cerec biogeneric reference technique: A case report. Journal of Dental Research, Dental Clinics, Dental Prospects, 7(2):112-118.

Abstract

Biogeneric Reference Technique (BRT) of the CEREC 3D v.3.8 software is an effective technique for single anterior ceramic crowns because it provides computer-controlled match of the tooth form to the contralateral tooth. BRT also enables the fabrication of two or more anterior all-ceramic crowns simultaneously. This clinical report demonstrates the clinical application of BRT for designing and milling two central incisors in one appointment using a single optical impression. After completing the virtual design of the first central incisor, it was copied and a mirror image was created. The second central incisor was designed using this replicated image and therefore a computer-controlled symmetry was obtained. The crowns were milled from monolithic feldspathic ceramic blocks and adhesively luted with dual-cured resin cement following dentin conditioning. At the two-year follow-up appointment, the restorations were intact, no adverse effects were noted, and the resultant appearance was highly satisfactory for the patient. A step-by-step protocol is described from design to cementation of these restorations.

Abstract

Biogeneric Reference Technique (BRT) of the CEREC 3D v.3.8 software is an effective technique for single anterior ceramic crowns because it provides computer-controlled match of the tooth form to the contralateral tooth. BRT also enables the fabrication of two or more anterior all-ceramic crowns simultaneously. This clinical report demonstrates the clinical application of BRT for designing and milling two central incisors in one appointment using a single optical impression. After completing the virtual design of the first central incisor, it was copied and a mirror image was created. The second central incisor was designed using this replicated image and therefore a computer-controlled symmetry was obtained. The crowns were milled from monolithic feldspathic ceramic blocks and adhesively luted with dual-cured resin cement following dentin conditioning. At the two-year follow-up appointment, the restorations were intact, no adverse effects were noted, and the resultant appearance was highly satisfactory for the patient. A step-by-step protocol is described from design to cementation of these restorations.

Statistics

Altmetrics

Downloads

176 downloads since deposited on 05 Feb 2014
36 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, not refereed, original work
Communities & Collections:04 Faculty of Medicine > Center for Dental Medicine > Clinic for Fixed and Removable Prosthodontics
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2013
Deposited On:05 Feb 2014 10:18
Last Modified:31 May 2017 11:24
Publisher:Tabriz University of Medical Sciences
ISSN:2008-210X
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.5681/joddd.2013.020
PubMed ID:23875091

Download

Download PDF  'Simultaneous replacement of maxillary central incisors with Cerec biogeneric reference technique: A case report'.
Preview
Content: Accepted Version
Language: English
Filetype: PDF
Size: 8MB
View at publisher