Header

UZH-Logo

Maintenance Infos

Innovations in minimally invasive mitral valve pair


Sündermann, Simon H; Seeburger, Joerg; Scherman, Jacques; Mohr, Friedrich Wilhelm; Falk, Volkmar (2012). Innovations in minimally invasive mitral valve pair. Surgical Technology International, 22:207-212.

Abstract

Mitral valve (MV) insufficiency is the second most common heart valve disease represented in cardiac surgery. The gold standard therapy is surgical repair of the valve. Today, most centers prefer a minimally invasive approach through a right-sided mini-thoracotomy. Despite the small access, there is still the need to use cardiopulmonary bypass (CPB), and the operation has to be performed on the arrested heart. New devices have been developed to optimize the results of surgical repair by implementing mechanisms for post-implantation adjustment on the beating heart or the avoidance of CPB. Early attempts with adjustable mitral annuloplasty rings go back to the early 1990s. Only a few devices are available on the market. Recently, a mitral valve adjustable annuloplasty ring was CE-marked and is under further clinical investigation. In addition, a sutureless annuloplasty band to be implanted on the beating heart is under preclinical and initial clinical investigation for transatrial and transfemoral transcatheter implantation. Furthermore, new neochord systems are being developed, which allow for functional length adjustment on the beating heart after implantation. Some devices were developed for percutaneous MV repair implanted into the coronary sinus to reshape the posterior MV annulus. Other percutaneous devices are directly fixed to the posterior annulus to alter its shape. Several disadvantages have been observed preventing a broad clinical use of some of these devices. There is a continuous effort to develop innovative techniques to optimize MV repair and to decrease invasiveness.

Abstract

Mitral valve (MV) insufficiency is the second most common heart valve disease represented in cardiac surgery. The gold standard therapy is surgical repair of the valve. Today, most centers prefer a minimally invasive approach through a right-sided mini-thoracotomy. Despite the small access, there is still the need to use cardiopulmonary bypass (CPB), and the operation has to be performed on the arrested heart. New devices have been developed to optimize the results of surgical repair by implementing mechanisms for post-implantation adjustment on the beating heart or the avoidance of CPB. Early attempts with adjustable mitral annuloplasty rings go back to the early 1990s. Only a few devices are available on the market. Recently, a mitral valve adjustable annuloplasty ring was CE-marked and is under further clinical investigation. In addition, a sutureless annuloplasty band to be implanted on the beating heart is under preclinical and initial clinical investigation for transatrial and transfemoral transcatheter implantation. Furthermore, new neochord systems are being developed, which allow for functional length adjustment on the beating heart after implantation. Some devices were developed for percutaneous MV repair implanted into the coronary sinus to reshape the posterior MV annulus. Other percutaneous devices are directly fixed to the posterior annulus to alter its shape. Several disadvantages have been observed preventing a broad clinical use of some of these devices. There is a continuous effort to develop innovative techniques to optimize MV repair and to decrease invasiveness.

Statistics

Citations

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Cardiovascular Surgery
Dewey Decimal Classification:610 Medicine & health
Language:German
Date:2012
Deposited On:28 Feb 2014 09:27
Last Modified:08 Dec 2017 03:29
Publisher:Universal Medical Press
ISSN:1090-3941
PubMed ID:23315719

Download

Full text not available from this repository.