Mitral regurgitation: quantification with 16-detector row CT - initial experience


Alkadhi, Hatem; Wildermuth, Simon; Bettex, Dominique A; Plass, André; Baumert, Bernhard; Leschka, Sebastian; Desbiolles, Lotus M; Marincek, Borut; Boehm, Thomas (2006). Mitral regurgitation: quantification with 16-detector row CT - initial experience. Radiology, 238(2):454-463.

Abstract

PURPOSE: To prospectively determine if retrospectively electrocardiographic (ECG)-gated multi-detector row computed tomography (CT) with a 16-detector row CT scanner can depict mitral regurgitation and enable quantification of the severity of the disease.
MATERIALS AND METHODS: The study had institutional review board approval, and patients gave informed consent. Nineteen patients with mitral regurgitation (10 men, nine women; mean age, 66 years +/- 9 [standard deviation]; range, 41-83 years) and 25 patients without mitral regurgitation (14 men, 11 women; mean age, 68 years +/- 9; range, 43-83 years) as determined with transesophageal color Doppler echocardiography and ventriculography underwent retrospectively ECG-gated 16-detector row CT. Twenty CT data sets covering the entire mitral valve apparatus were reconstructed in 5% steps of the R-R interval for each patient, and data analysis was performed with four-dimensional software. Using planimetry, two readers measured in consensus the area of the regurgitant orifice during systole. These measurements were compared with semiquantitative data from transesophageal echocardiography and ventriculography by using Spearman rank order correlation coefficients.
RESULTS: In the 25 patients without mitral regurgitation, no regurgitant orifice during systole could be detected with multi-detector row CT. In the 19 patients with mitral regurgitation, a regurgitant orifice could be visualized in all cases. The mean regurgitant orifice area at CT-45 mm(2) +/- 34 (range, 10-148 mm(2))-correlated significantly with the results at transesophageal echocardiography (r = 0.807, P < .001) and ventriculography (r = 0.922, P < .001).
CONCLUSION: Planimetric measurements of the regurgitant orifice area at retrospectively ECG-gated 16-detector row CT enable quantification of mitral regurgitation.

Abstract

PURPOSE: To prospectively determine if retrospectively electrocardiographic (ECG)-gated multi-detector row computed tomography (CT) with a 16-detector row CT scanner can depict mitral regurgitation and enable quantification of the severity of the disease.
MATERIALS AND METHODS: The study had institutional review board approval, and patients gave informed consent. Nineteen patients with mitral regurgitation (10 men, nine women; mean age, 66 years +/- 9 [standard deviation]; range, 41-83 years) and 25 patients without mitral regurgitation (14 men, 11 women; mean age, 68 years +/- 9; range, 43-83 years) as determined with transesophageal color Doppler echocardiography and ventriculography underwent retrospectively ECG-gated 16-detector row CT. Twenty CT data sets covering the entire mitral valve apparatus were reconstructed in 5% steps of the R-R interval for each patient, and data analysis was performed with four-dimensional software. Using planimetry, two readers measured in consensus the area of the regurgitant orifice during systole. These measurements were compared with semiquantitative data from transesophageal echocardiography and ventriculography by using Spearman rank order correlation coefficients.
RESULTS: In the 25 patients without mitral regurgitation, no regurgitant orifice during systole could be detected with multi-detector row CT. In the 19 patients with mitral regurgitation, a regurgitant orifice could be visualized in all cases. The mean regurgitant orifice area at CT-45 mm(2) +/- 34 (range, 10-148 mm(2))-correlated significantly with the results at transesophageal echocardiography (r = 0.807, P < .001) and ventriculography (r = 0.922, P < .001).
CONCLUSION: Planimetric measurements of the regurgitant orifice area at retrospectively ECG-gated 16-detector row CT enable quantification of mitral regurgitation.

Statistics

Citations

60 citations in Web of Science®
82 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Institute of Anesthesiology
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2006
Deposited On:18 Mar 2014 16:05
Last Modified:05 Apr 2016 17:38
Publisher:Radiological Society of North America
ISSN:0033-8419
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1148/radiol.2381042216
PubMed ID:16371578

Download

Full text not available from this repository.
View at publisher

TrendTerms

TrendTerms displays relevant terms of the abstract of this publication and related documents on a map. The terms and their relations were extracted from ZORA using word statistics. Their timelines are taken from ZORA as well. The bubble size of a term is proportional to the number of documents where the term occurs. Red, orange, yellow and green colors are used for terms that occur in the current document; red indicates high interlinkedness of a term with other terms, orange, yellow and green decreasing interlinkedness. Blue is used for terms that have a relation with the terms in this document, but occur in other documents.