Aortic stenosis: comparative evaluation of 16-detector row CT and echocardiography


Alkadhi, Hatem; Wildermuth, Simon; Plass, Andre; Bettex, Dominique; Baumert, Bernhard; Leschka, Sebastian; Desbiolles, Lotus M; Marincek, Borut; Boehm, Thomas (2006). Aortic stenosis: comparative evaluation of 16-detector row CT and echocardiography. Radiology, 240(1):47-55.

Abstract

PURPOSE: To prospectively evaluate whether planimetric measurements of aortic valve area (AVA) with 16-detector row computed tomography (CT) allow classification of aortic stenosis (AS).
MATERIALS AND METHODS: The study had institutional review board approval; patients gave informed consent. Twenty patients (11 men, nine women; mean age, 63 years) with AS and 20 patients (10 men, 10 women; mean age, 65 years) without underwent transthoracic echocardiography (TTE), transesophageal echocardiography (TEE), and retrospectively electrocardiographically gated 16-detector row CT. Twenty CT data sets were reconstructed in 5% steps of R-R interval; data analysis was performed with four-dimensional software. Maximum AVA in systole planimetrically measured with CT (AVA(CT)) was compared with AVA planimetrically measured with TEE (AVA(TEE)), AVA calculated with the continuity equation and TTE (AVA(TTE)), and transvalvular pressure gradients determined with the Bernoulli equation and TTE. Correlations among AVA(CT), AVA(TTE), AVA(TEE), and transvalvular pressure gradients were tested with bivariate regression analysis; agreement between methods was assessed with the Bland-Altman method.
RESULTS: In patients without AS, mean AVA(CT) was 3.56 cm2 +/- 0.66 and mean AVA(TEE) was 3.43 cm2 +/- 0.69. In patients with AS, mean AVA(CT) was 0.89 cm2 +/- 0.35; mean AVA(TEE), 0.86 cm2 +/- 0.35; and mean AVA(TTE), 0.83 cm2 +/- 0.33. Mean transvalvular pressure gradient was 51 mm Hg +/- 22. Significant correlations were present between AVA(CT) and AVA(TEE) (r = 0.99, P < .001), AVA(CT) and AVA(TTE) (r = 0.95, P < .001), and AVA(CT) and transvalvular pressure gradients (r = -0.74, P < .01). Mean differences were -0.08 cm2 (limits of agreement: -0.32, 0.16) for AVA(CT) versus AVA(TEE) and 0.06 cm2 (limits of agreement: -0.15, 0.26) for AVA(CT) versus AVA(TTE).
CONCLUSION: Planimetric measurements of AVA with retrospectively electrocardiographically gated 16-detector row CT allow classification of AS that is similar to that achieved with measurements by using echocardiographic methods.

Abstract

PURPOSE: To prospectively evaluate whether planimetric measurements of aortic valve area (AVA) with 16-detector row computed tomography (CT) allow classification of aortic stenosis (AS).
MATERIALS AND METHODS: The study had institutional review board approval; patients gave informed consent. Twenty patients (11 men, nine women; mean age, 63 years) with AS and 20 patients (10 men, 10 women; mean age, 65 years) without underwent transthoracic echocardiography (TTE), transesophageal echocardiography (TEE), and retrospectively electrocardiographically gated 16-detector row CT. Twenty CT data sets were reconstructed in 5% steps of R-R interval; data analysis was performed with four-dimensional software. Maximum AVA in systole planimetrically measured with CT (AVA(CT)) was compared with AVA planimetrically measured with TEE (AVA(TEE)), AVA calculated with the continuity equation and TTE (AVA(TTE)), and transvalvular pressure gradients determined with the Bernoulli equation and TTE. Correlations among AVA(CT), AVA(TTE), AVA(TEE), and transvalvular pressure gradients were tested with bivariate regression analysis; agreement between methods was assessed with the Bland-Altman method.
RESULTS: In patients without AS, mean AVA(CT) was 3.56 cm2 +/- 0.66 and mean AVA(TEE) was 3.43 cm2 +/- 0.69. In patients with AS, mean AVA(CT) was 0.89 cm2 +/- 0.35; mean AVA(TEE), 0.86 cm2 +/- 0.35; and mean AVA(TTE), 0.83 cm2 +/- 0.33. Mean transvalvular pressure gradient was 51 mm Hg +/- 22. Significant correlations were present between AVA(CT) and AVA(TEE) (r = 0.99, P < .001), AVA(CT) and AVA(TTE) (r = 0.95, P < .001), and AVA(CT) and transvalvular pressure gradients (r = -0.74, P < .01). Mean differences were -0.08 cm2 (limits of agreement: -0.32, 0.16) for AVA(CT) versus AVA(TEE) and 0.06 cm2 (limits of agreement: -0.15, 0.26) for AVA(CT) versus AVA(TTE).
CONCLUSION: Planimetric measurements of AVA with retrospectively electrocardiographically gated 16-detector row CT allow classification of AS that is similar to that achieved with measurements by using echocardiographic methods.

Statistics

Citations

76 citations in Web of Science®
86 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Institute of Anesthesiology
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:2006
Deposited On:18 Mar 2014 16:10
Last Modified:08 Dec 2017 03:58
Publisher:Radiological Society of North America
ISSN:0033-8419
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1148/radiol.2393050458
PubMed ID:16709791

Download

Full text not available from this repository.
View at publisher