How many radiographs are needed to detect angular stable head screw cut outs of the proximal humerus - A cadaver study


Spross, Christian; Jost, Bernhard; Rahm, Stefan; Winklhofer, Sebastian; Erhardt, Johannes; Benninger, Emanuel (2014). How many radiographs are needed to detect angular stable head screw cut outs of the proximal humerus - A cadaver study. Injury, 45(10):1557-1563.

Abstract

INTRODUCTION: Cut out of locking head screws is the most common complication of locking plates in fracture fixation of the proximal humerus with potentially disastrous consequences. Aim of the study was to find the single best and combination of radiographic projections to reliably detect screw cut outs.
MATERIALS AND METHODS: The locking plate was fixed to six cadaveric proximal humeri. Six different radiographs were performed: anteriorposterior in internal (apIR), in neutral (ap0) and in 30° external rotation (apER); axial in 30° (ax30) and 60° (ax60) abduction and an outlet view. Each head screw (n=9) was sequentially exchanged to perforate the humeral head with the tip and all radiographs were repeated for each cut out. Randomized image reading by two blinded examiners for cut out was done for single projection and combinations.
RESULTS: Interrater agreement was 0.72-0.93. Best single projection was ax30 (sensitivity 76%) and the worst was the outlet view (sens. 17%). Standard combination of apIR/outlet reached a sens. of 54%. The best combination of two was: apER/ax30 (90% sens.), of three: apIR/apER/ax30 (96% sens.) and of four: apIR/ap0/apER/ax30 (100% sens.).
CONCLUSION: Standard radiographs (ap/outlet), especially in internal rotation, may miss nearly half of screw cut outs. Single best radiographic projection was an axial view with 30° abduction. To account for all cut outs and correct screw position a combination of four projections was needed. These simple and feasible intraoperative and postoperative radiographs help to detect screw perforations of the locking plate reliably.

Abstract

INTRODUCTION: Cut out of locking head screws is the most common complication of locking plates in fracture fixation of the proximal humerus with potentially disastrous consequences. Aim of the study was to find the single best and combination of radiographic projections to reliably detect screw cut outs.
MATERIALS AND METHODS: The locking plate was fixed to six cadaveric proximal humeri. Six different radiographs were performed: anteriorposterior in internal (apIR), in neutral (ap0) and in 30° external rotation (apER); axial in 30° (ax30) and 60° (ax60) abduction and an outlet view. Each head screw (n=9) was sequentially exchanged to perforate the humeral head with the tip and all radiographs were repeated for each cut out. Randomized image reading by two blinded examiners for cut out was done for single projection and combinations.
RESULTS: Interrater agreement was 0.72-0.93. Best single projection was ax30 (sensitivity 76%) and the worst was the outlet view (sens. 17%). Standard combination of apIR/outlet reached a sens. of 54%. The best combination of two was: apER/ax30 (90% sens.), of three: apIR/apER/ax30 (96% sens.) and of four: apIR/ap0/apER/ax30 (100% sens.).
CONCLUSION: Standard radiographs (ap/outlet), especially in internal rotation, may miss nearly half of screw cut outs. Single best radiographic projection was an axial view with 30° abduction. To account for all cut outs and correct screw position a combination of four projections was needed. These simple and feasible intraoperative and postoperative radiographs help to detect screw perforations of the locking plate reliably.

Statistics

Citations

5 citations in Web of Science®
6 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Diagnostic and Interventional Radiology
04 Faculty of Medicine > Institute of Legal Medicine
Dewey Decimal Classification:340 Law
610 Medicine & health
Language:English
Date:October 2014
Deposited On:01 Oct 2014 14:14
Last Modified:08 Dec 2017 07:16
Publisher:Elsevier
ISSN:0020-1383
Publisher DOI:https://doi.org/10.1016/j.injury.2014.05.025
PubMed ID:24934611

Download

Full text not available from this repository.
View at publisher