Publication:

Accuracy of non-invasive continuous total hemoglobin measurement by Pulse CO-Oximetry in severe traumatized and surgical bleeding patients

Date

Date

Date
2017
Journal Article
Published version

Citations

Citation copied

Baulig, W., Seifert, B., Spahn, D. R., & Theusinger, O. M. (2017). Accuracy of non-invasive continuous total hemoglobin measurement by Pulse CO-Oximetry in severe traumatized and surgical bleeding patients. Journal of Clinical Monitoring and Computing, 31(1), 177–185. https://doi.org/10.1007/s10877-015-9816-2

Abstract

Abstract

Abstract

The Masimo Radical-7 Pulse CO-Oximeter (Masimo Corp., USA) non-invasively computes hemoglobin concentration (SpHb). SpHb was compared to Co-Oximeter readings (CoOxHb) of arterial samples in surgery patients of the emergency department. Forty-six patients were enrolled. The Masimo R1 25L (revision F and G) adult adhesive sensor was attached to the ring finger of the arterially cannulated hand. Before start, every 30 min during surgery and in the case of severe bleeding SpHb and CoOxHb values were documented. SpHb and post hoc adjusted

Metrics

Views

186 since deposited on 2016-01-12
Acq. date: 2025-11-12

Additional indexing

Creators (Authors)

  • Baulig, Werner
    affiliation.icon.alt
  • Seifert, Burkhardt
    affiliation.icon.alt
  • Spahn, Donat R
    affiliation.icon.alt
  • Theusinger, Oliver M
    affiliation.icon.alt

Journal/Series Title

Journal/Series Title

Journal/Series Title

Volume

Volume

Volume
31

Number

Number

Number
1

Page range/Item number

Page range/Item number

Page range/Item number
177

Page end

Page end

Page end
185

Item Type

Item Type

Item Type
Journal Article

Dewey Decimal Classifikation

Dewey Decimal Classifikation

Dewey Decimal Classifikation

Language

Language

Language
English

Publication date

Publication date

Publication date
2017

Date available

Date available

Date available
2016-01-12

Publisher

Publisher

Publisher

ISSN or e-ISSN

ISSN or e-ISSN

ISSN or e-ISSN
1387-1307

OA Status

OA Status

OA Status
Closed

PubMed ID

PubMed ID

PubMed ID

Metrics

Views

186 since deposited on 2016-01-12
Acq. date: 2025-11-12

Citations

Citation copied

Baulig, W., Seifert, B., Spahn, D. R., & Theusinger, O. M. (2017). Accuracy of non-invasive continuous total hemoglobin measurement by Pulse CO-Oximetry in severe traumatized and surgical bleeding patients. Journal of Clinical Monitoring and Computing, 31(1), 177–185. https://doi.org/10.1007/s10877-015-9816-2

Closed
Loading...
Thumbnail Image

Permanent URL

Permanent URL

Permanent URL
No files available