Publication:

Comparison of the diagnostic value of a small, single channel, electrocardiogram monitoring patch with a standard 3-lead Holter system over 24 hours in dogs

Date

Date

Date
2023
Journal Article
Published version

Citations

Citation copied

Schreiber, N., Willis, R., Glaus, T., & Baron Toaldo, M. (2023). Comparison of the diagnostic value of a small, single channel, electrocardiogram monitoring patch with a standard 3-lead Holter system over 24 hours in dogs. Journal of Veterinary Cardiology, 47, 47–54. https://doi.org/10.1016/j.jvc.2023.04.004

Abstract

Abstract

Abstract

Introduction/Objectives: The aim of this study was to compare a novel small event recorder device, the Carnation Ambulatory Monitor (CAM), with a standard Holter. Animals: Nineteen adult dogs. Material and methods: Comparative and explorative study. The two devices were simultaneously applied for approximately 24 h. Results: Analysis time (P=0.013) and percentage of artefacts (P<0.001) were greater for the CAM (110 min [40–264]; and 9% [0–34], respectively) compared to a standard Holter (30 min [18–270]; and 0.3% [0–9], respectively).

Metrics

Downloads

7 since deposited on 2023-07-19
Acq. date: 2025-11-13

Views

1 since deposited on 2023-07-19
Acq. date: 2025-11-13

Additional indexing

Creators (Authors)

Journal/Series Title

Journal/Series Title

Journal/Series Title

Volume

Volume

Volume
47

Page range/Item number

Page range/Item number

Page range/Item number
47

Page end

Page end

Page end
54

Item Type

Item Type

Item Type
Journal Article

Dewey Decimal Classifikation

Dewey Decimal Classifikation

Dewey Decimal Classifikation

Keywords

General Veterinary, Physiology

Language

Language

Language
English

Publication date

Publication date

Publication date
2023-06-01

Date available

Date available

Date available
2023-07-19

Publisher

Publisher

Publisher

ISSN or e-ISSN

ISSN or e-ISSN

ISSN or e-ISSN
1760-2734

OA Status

OA Status

OA Status
Hybrid

PubMed ID

PubMed ID

PubMed ID

Metrics

Downloads

7 since deposited on 2023-07-19
Acq. date: 2025-11-13

Views

1 since deposited on 2023-07-19
Acq. date: 2025-11-13

Citations

Citation copied

Schreiber, N., Willis, R., Glaus, T., & Baron Toaldo, M. (2023). Comparison of the diagnostic value of a small, single channel, electrocardiogram monitoring patch with a standard 3-lead Holter system over 24 hours in dogs. Journal of Veterinary Cardiology, 47, 47–54. https://doi.org/10.1016/j.jvc.2023.04.004

Hybrid Open Access
Loading...
Thumbnail Image

Files

Files

Files
Files available to download:1

Files

Files

Files
Files available to download:1
Loading...
Thumbnail Image