dc.date.issued2012
dc.description.abstractPURPOSE: To evaluate the effect of different cleaning media on the adhesion of resin cement to feldspathic ceramic after etching. MATERIALS AND METHODS: The cementation surfaces of ceramic blocks (N = 20, n = 5 per group) were etched with 10% hydrofluoric acid (HF) gel for 20 s and rinsed for 60 s. They were then randomly assigned to 4 groups: G1: air-water spray+drying (control); G2: ultrasonic cleaning in distilled water for 4 min+drying; G3: ultrasonic cleaning in 99.5% acetone for 4 min+drying; G4: ultrasonic cleaning in 70% alcohol for 4 min+drying. The ceramic blocks were silanized and cemented (RelyX ARC) to the composite blocks. Subsequently, the microtensile bond strength test (µTBS) was performed. In addition, EDS analysis was made to assess the elemental composition of the conditioned and cleaned ceramic surfaces. RESULTS: A significantly higher mean µTBS was obtained when specimens had been ultrasonically cleaned in distilled water (G2: 18.8 ± 0.4 MPa) (p < 0.05) compared to other groups (G1: 16.6 ± 0.5; G3: 16.1 ± 0.9; G4: 15.8 ± 1.4) (one-way ANOVA). EDS analysis indicated the presence of F- only in G1. Dissolved precipitates after HF etching were removed by ultrasonic cleaning. CONCLUSION: Cleaning the HF-etched ceramic surface ultrasonically in distilled water is recommended, instead of rinsing it with air-water spray only.
dc.identifier.doi10.3290/j.jad.a28625
dc.identifier.issn1461-5185
dc.identifier.scopus2-s2.0-84874427149
dc.identifier.urihttps://www.zora.uzh.ch/handle/20.500.14742/233269
dc.identifier.wos000312468300002
dc.language.isoeng
dc.subject.ddc610 Medicine & health
dc.titleDoes the ultrasonic cleaning medium affect the adhesion of resin cement to feldspathic ceramic?
dc.typearticle
dcterms.accessRightsinfo:eu-repo/semantics/restrictedAccess
dcterms.bibliographicCitation.journaltitleJournal of Adhesive Dentistry
dcterms.bibliographicCitation.number6
dcterms.bibliographicCitation.originalpublishernameQuintessence Publishing
dcterms.bibliographicCitation.pageend509
dcterms.bibliographicCitation.pagestart507
dcterms.bibliographicCitation.pmid23240109
dcterms.bibliographicCitation.volume14
dspace.entity.typePublicationen
uzh.contributor.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#
uzh.contributor.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#
uzh.contributor.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#
uzh.contributor.affiliationUNESP-Universidade Estadual Paulista
uzh.contributor.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#
uzh.contributor.affiliationUniversity of Zurich
uzh.contributor.authorMartins, Maria Elizabeth
uzh.contributor.authorLeite, Fabíola Pessoa
uzh.contributor.authorQueiroz, José Renato
uzh.contributor.authorVanderlei, Aleska Dias
uzh.contributor.authorReskalla, Helcio Nagib
uzh.contributor.authorÖzcan, Mutlu
uzh.contributor.correspondenceYes
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.document.availabilitynone
uzh.eprint.datestamp2013-03-07 12:34:43
uzh.eprint.lastmod2025-08-08 01:41:53
uzh.eprint.statusChange2013-03-07 12:34:43
uzh.harvester.ethYes
uzh.harvester.nbNo
uzh.identifier.doi10.5167/uzh-75473
uzh.jdb.eprintsId24821
uzh.oastatus.zoraClosed
uzh.publication.citationMartins, Maria Elizabeth; Leite, Fabíola Pessoa; Queiroz, José Renato; Vanderlei, Aleska Dias; Reskalla, Helcio Nagib; Özcan, Mutlu (2012). Does the ultrasonic cleaning medium affect the adhesion of resin cement to feldspathic ceramic? Journal of Adhesive Dentistry, 14(6):507-509.
uzh.publication.originalworkoriginal
uzh.publication.publishedStatusfinal
uzh.scopus.impact23
uzh.scopus.subjectsOrthodontics
uzh.scopus.subjectsOral Surgery
uzh.scopus.subjectsPeriodontics
uzh.workflow.doajuzh.workflow.doaj.false
uzh.workflow.eprintid75473
uzh.workflow.fulltextStatusrestricted
uzh.workflow.revisions96
uzh.workflow.rightsCheckkeininfo
uzh.workflow.statusarchive
uzh.wos.impact20
Files

Original bundle

Name:
04_Does_the_ultrasonic_cleaning_medium_acc.pdf
Size:
845.15 KB
Format:
Adobe Portable Document Format
Downloadable by admins only
Name:
04_Does_the_ultrasonic_cleaning_medium_pub.pdf
Size:
309.41 KB
Format:
Adobe Portable Document Format
Downloadable by admins only
Publication available in collections: