Publication:

Comparison of SLA(®) or SLActive(®) implants placed in the maxillary sinus with or without synthetic bone graft materials - an animal study in sheep

Date

Date

Date
2014
Journal Article
Published version
cris.lastimport.scopus2025-07-28T03:35:34Z
cris.lastimport.wos2025-08-10T01:31:03Z
dc.contributor.institutionUniversity of Zurich
dc.date.accessioned2013-12-18T08:06:43Z
dc.date.available2013-12-18T08:06:43Z
dc.date.issued2014-10
dc.description.abstract

AIMS: To assess the influence of an activated implant surface and a synthetic graft material in the maxillary sinus in combination with sinus floor elevation on bone-to-implant contact (BIC) as compared to implants with conventional surfaces. MATERIAL AND METHODS: In 16 sheep, sinus bone augmentation was performed using a synthetic bone graft material according to the methods described by Haas et al (Clinical Oral Implants Research, 9, 1998, 107; Clinical Oral Implants Research, 13, 2002, 396). Another 16 sheep received a sinus floor elevation procedure without graft material. Using a paired design, in one sinus of each animal, a conventional implant was placed, whereas an implant with activated surface was placed in the other. Eight animals of each group were sacrificed at 12 weeks and the others at 26 weeks after surgery. Histological analysis was performed to analyse BIC. Results were statistically compared at a significance level of P < 0.05. RESULTS: After 12 weeks, the BIC for conventional and activated implants with or without graft showed comparable results, with mean values of 14.8%, 16.5%, 21.5% and 20.1% (P > 0.05). For ungrafted sinuses after 26 weeks, no increase in BIC was recorded (12.1% conventional surface, 15.8% activated surface; P > 0.05). In grafted sinuses after 26 weeks, mean values increased to 28.7% for conventional and 34.1% for activated implants (P = 0.014; P = 0.015). However, only BIC of the latter was statistically significantly higher compared with ungrafted sinuses (P = 0.038). CONCLUSION: After 12 weeks of healing, neither grafting nor implant type seemed to influence BIC. Use of an activated implant surface did not increase BIC when compared with a conventional implant. The synthetic graft seemed to improve BIC values after 26 weeks.

dc.identifier.doi10.1111/clr.12255
dc.identifier.issn0905-7161
dc.identifier.scopus2-s2.0-84908654113
dc.identifier.urihttps://www.zora.uzh.ch/handle/20.500.14742/97687
dc.identifier.wos000342904800007
dc.language.isodeu
dc.subject.ddc610 Medicine & health
dc.title

Comparison of SLA(®) or SLActive(®) implants placed in the maxillary sinus with or without synthetic bone graft materials - an animal study in sheep

dc.typearticle
dcterms.accessRightsinfo:eu-repo/semantics/restrictedAccess
dcterms.bibliographicCitation.journaltitleClinical Oral Implants Research
dcterms.bibliographicCitation.number10
dcterms.bibliographicCitation.originalpublishernameWiley-Blackwell
dcterms.bibliographicCitation.pageend1148
dcterms.bibliographicCitation.pagestart1142
dcterms.bibliographicCitation.pmid24112524
dcterms.bibliographicCitation.volume25
dspace.entity.typePublicationen
uzh.contributor.affiliationUniversity of Zurich
uzh.contributor.affiliationDunedin School of Dentistry
uzh.contributor.affiliationInstitut für Sozial- und Präventivmedizin
uzh.contributor.affiliationUniversity of Zurich
uzh.contributor.affiliationUniversity of Zurich
uzh.contributor.affiliationUniversity of Zurich, Dunedin School of Dentistry
uzh.contributor.authorPhilipp, Alexander
uzh.contributor.authorDuncan, Warwick
uzh.contributor.authorRoos, Malgorzata
uzh.contributor.authorHämmerle, Christoph H
uzh.contributor.authorAttin, Thomas
uzh.contributor.authorSchmidlin, Patrick R
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceYes
uzh.document.availabilitynone
uzh.eprint.datestamp2013-12-18 08:06:43
uzh.eprint.lastmod2025-08-10 01:52:21
uzh.eprint.statusChange2013-12-18 08:06:43
uzh.harvester.ethYes
uzh.harvester.nbNo
uzh.identifier.doi10.5167/uzh-86789
uzh.jdb.eprintsId13311
uzh.oastatus.unpaywallclosed
uzh.oastatus.zoraClosed
uzh.publication.citationPhilipp, Alexander; Duncan, Warwick; Roos, Malgorzata; Hämmerle, Christoph H; Attin, Thomas; Schmidlin, Patrick R (2014). Comparison of SLA(®) or SLActive(®) implants placed in the maxillary sinus with or without synthetic bone graft materials - an animal study in sheep. Clinical Oral Implants Research, 25(10):1142-1148.
uzh.publication.originalworkoriginal
uzh.publication.publishedStatusfinal
uzh.scopus.impact30
uzh.scopus.subjectsOral Surgery
uzh.workflow.doajuzh.workflow.doaj.false
uzh.workflow.eprintid86789
uzh.workflow.fulltextStatusrestricted
uzh.workflow.revisions66
uzh.workflow.rightsCheckkeininfo
uzh.workflow.statusarchive
uzh.wos.impact28
Files

Original bundle

Name:
21_Philipp_SinusSheep_ClinOralImplaRes_2013.pdf
Size:
274.35 KB
Format:
Adobe Portable Document Format
Downloadable by admins only
Publication available in collections: