Aufgrund des stetig wachsenden Drucks - ausgelöst von automatisiertem Datenverkehr (z.B. Bots, Crawler und DDoS-Attacken) - sind unsere Server immer öfter so ausgelastet, dass ZORA nicht mehr erreichbar ist. Dies wird weltweit von weiteren Repositorien berichtet. Wir arbeiten unter Hochdruck daran, wenigstens den UZH-Mitgliedern Zugriff zu bieten über das UZH-Netzwerk oder VPN. Danke für Ihre Geduld.

Due to the ever-increasing pressure caused by automated data traffic (e.g., bots, crawlers, and DDoS attacks), our servers are increasingly overloaded, making ZORA inaccessible. This has been reported by other repositories around the world. We are working around the clock to ensure that at least UZH members can access the platform via the UZH network or VPN. Thank you for your patience.

 

Publication:

Point-to-point registration with mandibulo-maxillary splint in open and closed jaw position. Evaluation of registration accuracy for computer-aided surgery of the mandible

Date

Date

Date
2012
Journal Article
Published version
cris.lastimport.scopus2025-07-19T03:37:56Z
cris.lastimport.wos2025-08-07T01:31:52Z
cris.virtual.orcidhttps://orcid.org/0000-0002-2884-4008
cris.virtualsource.orcid4613b7e6-7652-49da-9133-651823a7fe2d
dc.contributor.institutionUniversity of Zurich
dc.date.accessioned2012-02-22T12:42:19Z
dc.date.available2012-02-22T12:42:19Z
dc.date.issued2012
dc.description.abstract

INTRODUCTION: Computer navigation plays an increasingly important role in craniomaxillofacial surgery. The difficulties in computer navigation at the craniomaxillofacial site lie in the accurate transmission of the dataset to the operating room. This study investigates the accuracy of the dental-splint registration method for the skull, midface, and mandible. MATERIAL AND METHODS: A synthetic human skull model was prepared with landmarks and scanned with cone beam computer tomography (CBCT). Two registration splints fixed the mandible against the viscerocranium in two different positions (closed vs. open). The target registration error was computed in all 278 landmarks spread over the entire skull and mandible in 10 repeated measurements using the VectorVision(2) (BrainLAB Inc., Feldkirchen, Germany) navigation system. RESULTS: If registered in the closed position an average precision of 2.07mm with a standard deviation (SD) of 0.78mm was computed for all landmarks distributed over the whole skull. Registration in the open position resulted in an average precision of 1.53mm (SD=0.55mm). For single landmarks the precision decreases linearly with distance from the reference markers. The longer the three-dimensional distance between the registration points, the more precise the computer navigation is, mainly in the most posterior area of the cranium. CONCLUSION: Our findings in the cranium are comparable with those of other studies. Artificial fixation of the lower jaw via splint seems to introduce no additional error. The registration points should be as far apart from each other as possible during navigation with the splint.

dc.identifier.doi10.1016/j.jcms.2011.10.016
dc.identifier.issn1010-5182
dc.identifier.scopus2-s2.0-84865743248
dc.identifier.urihttps://www.zora.uzh.ch/handle/20.500.14742/70421
dc.identifier.wos000309947100007
dc.language.isoeng
dc.subject.ddc610 Medicine & health
dc.title

Point-to-point registration with mandibulo-maxillary splint in open and closed jaw position. Evaluation of registration accuracy for computer-aided surgery of the mandible

dc.typearticle
dcterms.accessRightsinfo:eu-repo/semantics/openAccess
dcterms.bibliographicCitation.journaltitleJournal of Cranio-Maxillofacial Surgery
dcterms.bibliographicCitation.number7
dcterms.bibliographicCitation.originalpublishernameElsevier
dcterms.bibliographicCitation.pageend598
dcterms.bibliographicCitation.pagestart592
dcterms.bibliographicCitation.pmid22079336
dcterms.bibliographicCitation.volume40
dspace.entity.typePublicationen
uzh.contributor.affiliationUniversitatsSpital Zurich
uzh.contributor.affiliationUniversitatsSpital Zurich
uzh.contributor.affiliationBrigham and Women's Hospital
uzh.contributor.affiliationUniversitatsSpital Zurich
uzh.contributor.affiliationUniversitatsSpital Zurich
uzh.contributor.affiliationUniversitatsSpital Zurich
uzh.contributor.affiliation#PLACEHOLDER_PARENT_METADATA_VALUE#
uzh.contributor.authorBettschart, C
uzh.contributor.authorKruse, A
uzh.contributor.authorMatthews, F
uzh.contributor.authorZemann, W
uzh.contributor.authorObwegeser, J A
uzh.contributor.authorGrätz, K W
uzh.contributor.authorLübbers, H T
uzh.contributor.correspondenceYes
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.document.availabilitypostprint
uzh.eprint.datestamp2012-02-22 12:42:19
uzh.eprint.lastmod2025-08-07 01:37:53
uzh.eprint.statusChange2012-02-22 12:42:19
uzh.harvester.ethYes
uzh.harvester.nbNo
uzh.identifier.doi10.5167/uzh-60007
uzh.jdb.eprintsId29972
uzh.oastatus.unpaywallgreen
uzh.oastatus.zoraGreen
uzh.publication.citationBettschart, C., Kruse, A., Matthews, F., Zemann, W., Obwegeser, J. A., Grätz, K. W., & Lübbers, H. T. (2012). Point-to-point registration with mandibulo-maxillary splint in open and closed jaw position. Evaluation of registration accuracy for computer-aided surgery of the mandible. Journal of Cranio-Maxillofacial Surgery, 40, 592–598. https://doi.org/10.1016/j.jcms.2011.10.016
uzh.publication.originalworkoriginal
uzh.publication.publishedStatusfinal
uzh.scopus.impact45
uzh.scopus.subjectsSurgery
uzh.scopus.subjectsOral Surgery
uzh.scopus.subjectsOtorhinolaryngology
uzh.workflow.doajuzh.workflow.doaj.false
uzh.workflow.eprintid60007
uzh.workflow.fulltextStatuspublic
uzh.workflow.revisions114
uzh.workflow.rightsCheckkeininfo
uzh.workflow.statusarchive
uzh.wos.impact37
Files

Original bundle

Name:
Bettschaft_et_al_Point-to-point_registration.pdf
Size:
1.11 MB
Format:
Adobe Portable Document Format
Publication available in collections: