Publication:

Intraoral digital scans-Part 1: Influence of ambient scanning light conditions on the accuracy (trueness and precision) of different intraoral scanners

Date

Date

Date
2020
Journal Article
Published version
cris.lastimport.scopus2025-06-07T03:42:17Z
cris.lastimport.wos2025-06-23T02:01:40Z
cris.virtual.orcidhttps://orcid.org/0000-0002-9623-6098
cris.virtualsource.orcid897056e5-e91d-44fc-8110-837317253107
dc.contributor.institutionUniversity of Zurich
dc.date.accessioned2021-01-27T14:24:12Z
dc.date.available2021-01-27T14:24:12Z
dc.date.issued2020-09
dc.description.abstract

STATEMENT OF PROBLEM Digital scans have increasingly become an alternative to conventional impressions. Although previous studies have analyzed the accuracy of the available intraoral scanners (IOSs), the effect of the light scanning conditions on the accuracy of those IOS systems remains unclear. PURPOSE The purpose of this in vitro study was to measure the impact of lighting conditions on the accuracy (trueness and precision) of different IOSs. MATERIAL AND METHODS A typodont was digitized by using an extraoral scanner (L2i; Imetric) to obtain a reference standard tessellation language (STL) file. Three IOSs were evaluated-iTero Element, CEREC Omnicam, and TRIOS 3-with 4 lighting conditions-chair light 10 000 lux, room light 1003 lux, natural light 500 lux, and no light 0 lux. Ten digital scans per group were recorded. The STL file was used as a reference to measure the discrepancy between the digitized typodont and digital scans by using the MeshLab software program. The Kruskal-Wallis, 1-way ANOVA, and pairwise comparison were used to analyze the data. RESULTS Significant differences for trueness and precision mean values were observed across different IOSs tested with the same lighting conditions and across different lighting conditions for a given IOS. In all groups, precision mean values were higher than their trueness values, indicating low relative precision. CONCLUSIONS Ambient lighting conditions influenced the accuracy (trueness and precision) of the IOSs tested. The recommended lighting conditions depend on the IOS selected. For iTero Element, chair and room light conditions resulted in better accuracy mean values. For CEREC Omnicam, zero light resulted in better accuracy, and for TRIOS 3, room light resulted in better accuracy.

dc.identifier.doi10.1016/j.prosdent.2019.06.003
dc.identifier.issn0022-3913
dc.identifier.scopus2-s2.0-85076003602
dc.identifier.urihttps://www.zora.uzh.ch/handle/20.500.14742/178961
dc.identifier.wos000568991000010
dc.language.isoeng
dc.subject.ddc610 Medicine & health
dc.title

Intraoral digital scans-Part 1: Influence of ambient scanning light conditions on the accuracy (trueness and precision) of different intraoral scanners

dc.typearticle
dcterms.accessRightsinfo:eu-repo/semantics/openAccess
dcterms.bibliographicCitation.journaltitleJournal of Prosthetic Dentistry
dcterms.bibliographicCitation.number3
dcterms.bibliographicCitation.originalpublishernameElsevier
dcterms.bibliographicCitation.pageend378
dcterms.bibliographicCitation.pagestart372
dcterms.bibliographicCitation.pmid31864638
dcterms.bibliographicCitation.volume124
dspace.entity.typePublicationen
uzh.contributor.affiliationTexas A&M University, University of Washington, Seattle, Revilla Research Center
uzh.contributor.affiliationTexas A&M University
uzh.contributor.affiliationPrivate Practice
uzh.contributor.affiliationUniversidad Complutense de Madrid, Revilla Research Center
uzh.contributor.affiliationTexas A&M University
uzh.contributor.affiliationUniversity of Zurich
uzh.contributor.affiliationTexas A&M University
uzh.contributor.authorRevilla-León, Marta
uzh.contributor.authorJiang, Peng
uzh.contributor.authorSadeghpour, Mehrad
uzh.contributor.authorPiedra-Cascón, Wenceslao
uzh.contributor.authorZandinejad, Amirali
uzh.contributor.authorÖzcan, Mutlu
uzh.contributor.authorKrishnamurthy, Vinayak R
uzh.contributor.correspondenceYes
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.document.availabilitynone
uzh.document.availabilitypostprint
uzh.eprint.datestamp2021-01-27 14:24:12
uzh.eprint.lastmod2025-06-23 02:07:21
uzh.eprint.statusChange2021-01-27 14:24:12
uzh.harvester.ethYes
uzh.harvester.nbNo
uzh.identifier.doi10.5167/uzh-198103
uzh.jdb.eprintsId11400
uzh.oastatus.unpaywallgreen
uzh.oastatus.zoraGreen
uzh.publication.citationRevilla-León, Marta; Jiang, Peng; Sadeghpour, Mehrad; Piedra-Cascón, Wenceslao; Zandinejad, Amirali; Özcan, Mutlu; Krishnamurthy, Vinayak R (2020). Intraoral digital scans-Part 1: Influence of ambient scanning light conditions on the accuracy (trueness and precision) of different intraoral scanners. Journal of Prosthetic Dentistry, 124(3):372-378.
uzh.publication.originalworkoriginal
uzh.publication.publishedStatusfinal
uzh.scopus.impact236
uzh.scopus.subjectsOral Surgery
uzh.workflow.doajuzh.workflow.doaj.false
uzh.workflow.eprintid198103
uzh.workflow.fulltextStatusrestricted
uzh.workflow.revisions43
uzh.workflow.rightsCheckkeininfo
uzh.workflow.sourcePubMed:PMID:31864638
uzh.workflow.statusarchive
uzh.wos.impact199
Files

Original bundle

Name:
45_acc.pdf
Size:
593.38 KB
Format:
Adobe Portable Document Format
Name:
45_pub.pdf
Size:
996.09 KB
Format:
Adobe Portable Document Format
Publication available in collections: