Publication:

Changes of radiopacity around implants of different lengths: Five-year follow-up data of a randomized clinical trial

Date

Date

Date
2020
Journal Article
Published version
cris.lastimport.scopus2025-06-06T03:37:33Z
cris.lastimport.wos2025-07-23T01:32:21Z
cris.virtual.orcidhttps://orcid.org/0000-0002-1377-0325
cris.virtualsource.orcid187c58f2-3cd9-428f-bb7a-ef8d5cf2f26a
dc.contributor.institutionUniversity of Zurich
dc.date.accessioned2021-01-07T07:46:16Z
dc.date.available2021-01-07T07:46:16Z
dc.date.issued2020-05
dc.description.abstract

OBJECTIVE To follow-up the radiographic changes in peri-implant bone of short (6 mm, test group) and long (10 mm, control group) single-unit implants five years after loading. MATERIALS AND METHODS Forty-three implants of the test and 44 implants of the control group could be reassessed from 96 originally included implants. Standardized areas of interest (AOI) were defined in the peri-implant bone at pre-defined locations at mid-length on both sides of the implants, and at the apex. An arbitrary mean grey scale value (GSV) was calculated for the AOI after brightness calibration of the radiographs. Changes for GSV were calculated and tested for possible inter- and intra-group differences using the Mann-Whitney and Wilcoxon tests. RESULTS The calculated intra-group differences between baseline and 5 years in the test group accounted for 2.4 ± 19.6 (i.e. slight brightening) and -6.2 ± 20.2 for the control group (i.e. slight shading), which resulted in a statistically significant difference in GSV change (p < .05). Crown-to-implant ratio was the only parameter showing an effect on GSV change (p = .001). CONCLUSIONS Assessing conventional radiographs, longer implants showed a slightly stronger change of radiopacity of the peri-implant bone (slight loss of density) than short ones (slightly enhanced density) after five years of loading.

dc.identifier.doi10.1111/clr.13584
dc.identifier.issn0905-7161
dc.identifier.scopus2-s2.0-85079364432
dc.identifier.urihttps://www.zora.uzh.ch/handle/20.500.14742/176010
dc.identifier.wos000512941400001
dc.language.isoeng
dc.subject.ddc610 Medicine & health
dc.title

Changes of radiopacity around implants of different lengths: Five-year follow-up data of a randomized clinical trial

dc.typearticle
dcterms.accessRightsinfo:eu-repo/semantics/openAccess
dcterms.bibliographicCitation.journaltitleClinical Oral Implants Research
dcterms.bibliographicCitation.number5
dcterms.bibliographicCitation.originalpublishernameWiley-Blackwell Publishing, Inc.
dcterms.bibliographicCitation.pageend494
dcterms.bibliographicCitation.pagestart488
dcterms.bibliographicCitation.pmid32003872
dcterms.bibliographicCitation.volume31
dspace.entity.typePublicationen
uzh.contributor.affiliationCenter of Dental Medicine
uzh.contributor.affiliationCenter of Dental Medicine
uzh.contributor.affiliationCenter of Dental Medicine
uzh.contributor.affiliationCenter of Dental Medicine
uzh.contributor.affiliationCenter of Dental Medicine
uzh.contributor.affiliationCenter of Dental Medicine
uzh.contributor.authorSluka, Benjamin
uzh.contributor.authorNaenni, Nadja
uzh.contributor.authorJung, Ronald E
uzh.contributor.authorAttin, Thomas
uzh.contributor.authorSchmidlin, Patrick R
uzh.contributor.authorSahrmann, Philipp
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceYes
uzh.contributor.correspondenceNo
uzh.document.availabilitypostprint
uzh.eprint.datestamp2021-01-07 07:46:16
uzh.eprint.lastmod2025-07-23 02:09:35
uzh.eprint.statusChange2021-01-07 07:46:16
uzh.harvester.ethYes
uzh.harvester.nbNo
uzh.identifier.doi10.5167/uzh-194451
uzh.jdb.eprintsId13311
uzh.note.publicThis is the peer reviewed version of the following article: Sluka, Benjamin; Naenni, Nadja; Jung, Ronald E; Attin, Thomas; Schmidlin, Patrick R; Sahrmann, Philipp (2020). Changes of radiopacity around implants of different lengths: Five-year follow-up data of a randomized clinical trial. Clinical Oral Implants Research, 31(5):488-494., which has been published in final form at https://doi.org/ 10.1111/clr.13584. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions. (http://www.wileyauthors.com/self-archiving)
uzh.oastatus.unpaywallgreen
uzh.oastatus.zoraGreen
uzh.publication.citationSluka, B., Naenni, N., Jung, R. E., Attin, T., Schmidlin, P. R., & Sahrmann, P. (2020). Changes of radiopacity around implants of different lengths: Five-year follow-up data of a randomized clinical trial. Clinical Oral Implants Research, 31, 488–494. https://doi.org/10.1111/clr.13584
uzh.publication.originalworkoriginal
uzh.publication.publishedStatusfinal
uzh.scopus.impact11
uzh.scopus.subjectsOral Surgery
uzh.workflow.doajuzh.workflow.doaj.false
uzh.workflow.eprintid194451
uzh.workflow.fulltextStatuspublic
uzh.workflow.revisions49
uzh.workflow.rightsCheckkeininfo
uzh.workflow.sourcePubMed:PMID:32003872
uzh.workflow.statusarchive
uzh.wos.impact11
Files

Original bundle

Name:
76_Sluka_Attin_BoneDensity_Clin_Oral_Implants_Res_2020-1.pdf
Size:
1.73 MB
Format:
Adobe Portable Document Format
Publication available in collections: