Publication:

Volumetric preload measurement by thermodilution: a comparison with transoesophageal echocardiography

Date

Date

Date
2005
Journal Article
Published version

Citations

Citation copied

Hofer, C. K., Furrer, L., Matter-Ensner, S., Maloigne, M., Klaghofer, R., Genoni, M., & Zollinger, A. (2005). Volumetric preload measurement by thermodilution: a comparison with transoesophageal echocardiography. British Journal of Anaesthesia, 94(6), 748–755. https://doi.org/10.1093/bja/aei123

Abstract

Abstract

Abstract

Background. End-diastolic volume indices determined by transpulmonary thermodilution and pulmonary artery thermodilution may give a better estimate of left ventricular preload than pulmonary capillary wedge pressure monitoring. The aim of this study was to compare volume preload monitoring using the two different thermodilution techniques with left ventricular preload assessment by transoesophageal echocardiography (TOE). Methods. Twenty patients undergoing elective cardiac surgery with preserved left-right ventricular function were s

Additional indexing

Creators (Authors)

  • Hofer, C K
    affiliation.icon.alt
  • Furrer, L
    affiliation.icon.alt
  • Matter-Ensner, S
    affiliation.icon.alt
  • Maloigne, M
    affiliation.icon.alt
  • Klaghofer, R
    affiliation.icon.alt
  • Genoni, M
    affiliation.icon.alt
  • Zollinger, A
    affiliation.icon.alt

Journal/Series Title

Journal/Series Title

Journal/Series Title

Volume

Volume

Volume
94

Number

Number

Number
6

Page range/Item number

Page range/Item number

Page range/Item number
748

Page end

Page end

Page end
755

Item Type

Item Type

Item Type
Journal Article

Dewey Decimal Classifikation

Dewey Decimal Classifikation

Dewey Decimal Classifikation

Language

Language

Language
English

Publication date

Publication date

Publication date
2005-06-01

Date available

Date available

Date available
2018-10-23

Publisher

Publisher

Publisher

ISSN or e-ISSN

ISSN or e-ISSN

ISSN or e-ISSN
0007-0912

OA Status

OA Status

OA Status
Hybrid

Free Access at

Free Access at

Free Access at
DOI

Citations

Citation copied

Hofer, C. K., Furrer, L., Matter-Ensner, S., Maloigne, M., Klaghofer, R., Genoni, M., & Zollinger, A. (2005). Volumetric preload measurement by thermodilution: a comparison with transoesophageal echocardiography. British Journal of Anaesthesia, 94(6), 748–755. https://doi.org/10.1093/bja/aei123

Hybrid Open Access
Loading...
Thumbnail Image

Files

Files

Files
Files available to download:1

Files

Files

Files
Files available to download:1
Loading...
Thumbnail Image