dc.description.abstract

Introduction: The COVID-19 pandemic has led to high demand of diagnostic tools. Rapid antigen detection tests have been developed and many have received regulatory acceptance such as CE IVD or FDA markings. Their performance needs to be carefully assessed. Materials and methods: 158 positive and 40 negative retrospective samples collected in saline and analyzed by a laboratory-developed RT-PCR test were used to evaluate Sofia (Quidel), Standard Q (SD Biosensor), and Panbio™ (Abbott) rapid antigen detection tests (RADTs). A subset of the specimens was subjected to virus culture. Results: The specificity of all RADTs was 100 % and the sensitivity and percent agreement was 80 % and 85 % for Sofia, 81 % and 85 % for Standard Q, and 83 % and 86 % for Panbio™, respectively. All three RADTs evaluated in this study reached a more than 90 % sensitivity for samples with a high viral load as estimated from the low Ct (Cycle threshold) values in the reference RT-PCR. Virus culture was successful in 80 % of specimens with a Ct value <25. Conclusions: As expected, the RADTs were less sensitive than RT-PCR. However, they benefit from the speed and ease of testing, and lower price as compared to RT-PCR. Repeated testing in appropriate settings may improve the overall performance.

dc.identifier.doi10.1016/j.jcv.2021.104785
dc.identifier.issn1386-6532
dc.identifier.scopus2-s2.0-85102111022
dc.identifier.urihttps://www.zora.uzh.ch/handle/20.500.14742/188208
dc.identifier.wos000636118800011
dc.language.isoeng
dc.subjectInfectious Diseases
dc.subjectVirology
dc.subject.ddc570 Life sciences; biology
dc.title

Evaluation of three rapid lateral flow antigen detection tests for the diagnosis of SARS-CoV-2 infection

dc.typearticle
dcterms.accessRightsinfo:eu-repo/semantics/restrictedAccess
dcterms.bibliographicCitation.journaltitleJournal of Clinical Virology
dcterms.bibliographicCitation.originalpublishernameElsevier
dcterms.bibliographicCitation.pagestart104785
dcterms.bibliographicCitation.volume137
dspace.entity.typePublicationen
uzh.contributor.affiliationHelsinki University Hospital
uzh.contributor.affiliationHelsinki University Hospital
uzh.contributor.affiliationHelsinki University Hospital
uzh.contributor.affiliationHelsingin Yliopisto
uzh.contributor.affiliationHelsinki Metropolia University of Applied Sciences
uzh.contributor.affiliationHelsinki University Hospital, Helsingin Yliopisto
uzh.contributor.affiliationHelsinki University Hospital
uzh.contributor.affiliationHelsingin Yliopisto, University of Zurich
uzh.contributor.affiliationHelsinki University Hospital
uzh.contributor.authorJääskeläinen, A E
uzh.contributor.authorAhava, M J
uzh.contributor.authorJokela, P
uzh.contributor.authorSzirovicza, L
uzh.contributor.authorPohjala, S
uzh.contributor.authorVapalahti, O
uzh.contributor.authorLappalainen, M
uzh.contributor.authorHepojoki, Jussi
uzh.contributor.authorKurkela, S
uzh.contributor.correspondenceYes
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.document.availabilitynone
uzh.eprint.datestamp2021-11-22 11:39:24
uzh.eprint.lastmod2025-07-25 01:38:14
uzh.eprint.statusChange2021-11-22 11:39:24
uzh.harvester.ethYes
uzh.harvester.nbNo
uzh.identifier.doi10.5167/uzh-209429
uzh.jdb.eprintsId29216
uzh.oastatus.unpaywallbronze
uzh.oastatus.zoraClosed
uzh.publication.citationJääskeläinen, A E; Ahava, M J; Jokela, P; Szirovicza, L; Pohjala, S; Vapalahti, O; Lappalainen, M; Hepojoki, Jussi; Kurkela, S (2021). Evaluation of three rapid lateral flow antigen detection tests for the diagnosis of SARS-CoV-2 infection. Journal of Clinical Virology, 137:104785.
uzh.publication.originalworkoriginal
uzh.publication.publishedStatusfinal
uzh.scopus.impact56
uzh.scopus.subjectsVirology
uzh.scopus.subjectsInfectious Diseases
uzh.workflow.doajuzh.workflow.doaj.false
uzh.workflow.eprintid209429
uzh.workflow.fulltextStatusrestricted
uzh.workflow.revisions41
uzh.workflow.rightsCheckkeininfo
uzh.workflow.sourceCrossRef:10.1016/j.jcv.2021.104785
uzh.workflow.statusarchive
uzh.wos.impact53
Files

Original bundle

Name:
mainelsevier.pdf
Size:
484.53 KB
Format:
Adobe Portable Document Format
Downloadable by admins only
Publication available in collections: