Publication:

Influence of cementation and cement type on the fracture load testing methodology of anterior crowns made of different materials

Date

Date

Date
2013
Journal Article
Published version

Citations

Citation copied

Stawarczyk, B., Beuer, F., Ender, A., Roos, M., Edelhoff, D., & Wimmer, T. (2013). Influence of cementation and cement type on the fracture load testing methodology of anterior crowns made of different materials. Dental Materials Journal, 32(6), 888–895. https://doi.org/10.4012/dmj.2013-147

Abstract

Abstract

Abstract

To evaluate the influence of cementation on fracture load of anterior crowns made of CAD/CAM-resin-blocks (ART), leucite-reinforced glass-ceramics (LRG), lithium disilicate ceramics (LIT), veneered zirconia (ZRO) and veneered alloy (DEG). Each crown group (n=15/subgroup) was cemented on the metal abutment as follows: i. using glass ionomer, ii. using self-adhesive resin cement, and iii. not cemented. Crowns were tested and analyzed with 2-way and 1-way ANOVA (Scheffé test), and Weibull statistics (p<0.05). Within LRG, self-adhesive ce

Metrics

Views

1 since deposited on 2014-01-15
Acq. date: 2025-11-13

Additional indexing

Creators (Authors)

  • Stawarczyk, Bogna
    affiliation.icon.alt
  • Beuer, Florian
    affiliation.icon.alt
  • Ender, Andreas
    affiliation.icon.alt
  • Roos, Malgorzata
    affiliation.icon.alt
  • Edelhoff, Daniel
    affiliation.icon.alt
  • Wimmer, Timea
    affiliation.icon.alt

Journal/Series Title

Journal/Series Title

Journal/Series Title

Volume

Volume

Volume
32

Number

Number

Number
6

Page range/Item number

Page range/Item number

Page range/Item number
888

Page end

Page end

Page end
895

Item Type

Item Type

Item Type
Journal Article

Dewey Decimal Classifikation

Dewey Decimal Classifikation

Dewey Decimal Classifikation

Language

Language

Language
English

Publication date

Publication date

Publication date
2013

Date available

Date available

Date available
2014-01-15

ISSN or e-ISSN

ISSN or e-ISSN

ISSN or e-ISSN
0287-4547

Additional Information

Additional Information

Additional Information
Change of name: Timea Lamper to Timea Wimmer

OA Status

OA Status

OA Status
Closed

Free Access at

Free Access at

Free Access at
DOI

PubMed ID

PubMed ID

PubMed ID

Metrics

Views

1 since deposited on 2014-01-15
Acq. date: 2025-11-13

Citations

Citation copied

Stawarczyk, B., Beuer, F., Ender, A., Roos, M., Edelhoff, D., & Wimmer, T. (2013). Influence of cementation and cement type on the fracture load testing methodology of anterior crowns made of different materials. Dental Materials Journal, 32(6), 888–895. https://doi.org/10.4012/dmj.2013-147

Closed
Loading...
Thumbnail Image

Files

Files

Files
Files available to download:2

Files

Files

Files
Files available to download:2
Loading...
Thumbnail Image