Publication: Initial apical fit of K-files versus LightSpeed LSX instruments assessed by micro-computed tomography
Initial apical fit of K-files versus LightSpeed LSX instruments assessed by micro-computed tomography
Date
Date
Date
| cris.lastimport.scopus | 2025-07-23T03:33:22Z | |
| cris.lastimport.wos | 2025-08-08T01:32:41Z | |
| dc.contributor.institution | University of Zurich | |
| dc.date.accessioned | 2013-01-28T08:01:22Z | |
| dc.date.available | 2013-01-28T08:01:22Z | |
| dc.date.issued | 2012 | |
| dc.description.abstract | AIM: To compare the apical fit in two dimensions of the first K-file versus the first Lightspeed LSX instrument binding at working length after an initial crown-down preparation. METHODOLOGY: Twenty maxillary molars with fully developed roots and four separate root canals were selected. Canals were pre-flared with ProFile.04 taper instruments to three quarters of estimated working length. Working length was electronically determined using a size 06 K-file. Progressively larger K-files were inserted passively to working length. The first binding K-file was termed initial apical file (IAF). Then, the first binding LSX initial apical lightspeed-instrument (IAL) was determined. Teeth were scanned with and without instruments in place using micro-computed tomography. Cross-sections of the apical part of the root canals were analysed as follows: the largest and smallest diameters of the root canal and the diameter of the instrument were calculated and related to each other. Statistics were performed using Kruskal-Wallis test and Wilcoxon test. The alpha-type error was set at 0.05. RESULTS: Initial apical file sizes ranged from 8 to 30 and were lowest in second mesiobuccal and highest in palatal canals. IAL sizes ranged from size 20 to 40. The apical large canal diameter was assessed more accurately by the LSX instruments (P < 0.0001). However, the smallest available LSX instrument (i.e. size 20) did not reach working length in 39 of 80 canals. Conclusions: Instruments with a flat widened tip were found to determine apical cross-sectional diameter better than round, tapered instruments. | |
| dc.identifier.doi | 10.1111/j.1365-2591.2011.01967.x | |
| dc.identifier.issn | 0143-2885 | |
| dc.identifier.scopus | 2-s2.0-84855781357 | |
| dc.identifier.uri | https://www.zora.uzh.ch/handle/20.500.14742/78323 | |
| dc.identifier.wos | 000298985200007 | |
| dc.language.iso | eng | |
| dc.subject.ddc | 610 Medicine & health | |
| dc.title | Initial apical fit of K-files versus LightSpeed LSX instruments assessed by micro-computed tomography | |
| dc.type | article | |
| dcterms.accessRights | info:eu-repo/semantics/restrictedAccess | |
| dcterms.bibliographicCitation.journaltitle | International Endodontic Journal | |
| dcterms.bibliographicCitation.number | 2 | |
| dcterms.bibliographicCitation.originalpublishername | Wiley-Blackwell | |
| dcterms.bibliographicCitation.pageend | 176 | |
| dcterms.bibliographicCitation.pagestart | 169 | |
| dcterms.bibliographicCitation.pmid | 21992481 | |
| dcterms.bibliographicCitation.volume | 45 | |
| dspace.entity.type | Publication | en |
| uzh.contributor.affiliation | University of Zurich | |
| uzh.contributor.affiliation | University of Zurich | |
| uzh.contributor.affiliation | University of Zurich | |
| uzh.contributor.author | Marending, M | |
| uzh.contributor.author | Schicht, O O | |
| uzh.contributor.author | Paqué, F | |
| uzh.contributor.correspondence | No | |
| uzh.contributor.correspondence | No | |
| uzh.contributor.correspondence | Yes | |
| uzh.document.availability | none | |
| uzh.eprint.datestamp | 2013-01-28 08:01:22 | |
| uzh.eprint.lastmod | 2025-08-08 01:38:32 | |
| uzh.eprint.statusChange | 2013-01-28 08:01:22 | |
| uzh.harvester.eth | Yes | |
| uzh.harvester.nb | No | |
| uzh.identifier.doi | 10.5167/uzh-70707 | |
| uzh.jdb.eprintsId | 20670 | |
| uzh.oastatus.unpaywall | closed | |
| uzh.oastatus.zora | Closed | |
| uzh.publication.citation | Marending, M; Schicht, O O; Paqué, F (2012). Initial apical fit of K-files versus LightSpeed LSX instruments assessed by micro-computed tomography. International Endodontic Journal, 45(2):169-176. | |
| uzh.publication.originalwork | original | |
| uzh.publication.publishedStatus | final | |
| uzh.scopus.impact | 9 | |
| uzh.scopus.subjects | General Dentistry | |
| uzh.workflow.doaj | uzh.workflow.doaj.false | |
| uzh.workflow.eprintid | 70707 | |
| uzh.workflow.fulltextStatus | restricted | |
| uzh.workflow.revisions | 64 | |
| uzh.workflow.rightsCheck | keininfo | |
| uzh.workflow.status | archive | |
| uzh.wos.impact | 7 | |
| Files | Original bundle
22_Marending_apical_fit_IEJ_2012_02.pdfview file |Download1.03 MB | |
| Publication available in collections: |