Publication:

Comparison of two different coagulation algorithms on the use of allogenic blood products and coagulation factors in severely injured trauma patients: a retrospective, multicentre, observational study

Date

Date

Date
2018
Journal Article
Published version

Citations

Citation copied

Kaserer, A., Casutt, M., Sprengel, K., Seifert, B., Spahn, D. R., & Stein, P. (2018). Comparison of two different coagulation algorithms on the use of allogenic blood products and coagulation factors in severely injured trauma patients: a retrospective, multicentre, observational study. Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 26:4. https://doi.org/10.1186/s13049-017-0463-0

Abstract

Abstract

Abstract

BACKGROUND:At the University Hospital Zurich (USZ) and the Cantonal Hospital of Lucerne (LUKS) an individualized goal-directed coagulation and transfusion algorithm was introduced and implemented before 2012 (Coagulation algorithm of the USZ: USZ-Alg; of the LUKS: LUKS-Alg). Main differences between both algorithms are: 1) A target haematocrit-range of 0.21-0.24 (USZ-Alg) vs. a lower haematocrit limit only (LUKS-Alg). 2) Blind coagulation-package in selected cases (LUKS-Alg only). 3) Factor XIII substitution is considered earlier acco

Additional indexing

Creators (Authors)

  • Kaserer, Alexander
    affiliation.icon.alt
  • Casutt, Mattias
    affiliation.icon.alt
  • Sprengel, Kai
    affiliation.icon.alt
  • Seifert, Burkhardt
    affiliation.icon.alt
  • Spahn, Donat R
    affiliation.icon.alt
  • Stein, Philipp
    affiliation.icon.alt

Journal/Series Title

Journal/Series Title

Journal/Series Title

Page range/Item number

Page range/Item number

Page range/Item number
26:4

Item Type

Item Type

Item Type
Journal Article

Dewey Decimal Classifikation

Dewey Decimal Classifikation

Dewey Decimal Classifikation

Language

Language

Language
German

Publication date

Publication date

Publication date
2018

Date available

Date available

Date available
2018-02-01

Publisher

Publisher

Publisher

ISSN or e-ISSN

ISSN or e-ISSN

ISSN or e-ISSN
1757-7241

OA Status

OA Status

OA Status
Gold

Free Access at

Free Access at

Free Access at
Pubmed ID

PubMed ID

PubMed ID

PubMed ID

Citations

Citation copied

Kaserer, A., Casutt, M., Sprengel, K., Seifert, B., Spahn, D. R., & Stein, P. (2018). Comparison of two different coagulation algorithms on the use of allogenic blood products and coagulation factors in severely injured trauma patients: a retrospective, multicentre, observational study. Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 26:4. https://doi.org/10.1186/s13049-017-0463-0

Gold Open Access
Loading...
Thumbnail Image

Files

Files

Files
Files available to download:1

Files

Files

Files
Files available to download:1
Loading...
Thumbnail Image