dc.description.abstract

PURPOSE To describe a chairside method for producing implant guides based solely on digital data and present a first assessment of in vitro accuracy on plaster models. MATERIAL AND METHODS Twenty-four implants were planned and pilot drillings were performed according to a new protocol, which is based on the registration of CBCT and CAD/CAM data. Chairside-milled one-piece drill guides were used to transfer the virtual plan into reality. Accuracy measurements were acquired. RESULTS Chairside-milled drill guides were successfully fabricated and accuracy for pilot drillings was between 0.17 and 1.3 mm. CONCLUSION Within the limits of this experimental study, chairside-milled drill guides are feasible and do not require any preparation before CBCT scanning.

dc.identifier.issn1463-4201
dc.identifier.scopus2-s2.0-84906922505
dc.identifier.urihttps://www.zora.uzh.ch/handle/20.500.14742/84370
dc.identifier.wos000209717200003
dc.language.isoeng
dc.subject.ddc610 Medicine & health
dc.title

Accuracy of chairside-milled CAD/CAM drill guides for dental implants

dc.typearticle
dcterms.accessRightsinfo:eu-repo/semantics/restrictedAccess
dcterms.bibliographicCitation.journaltitleInternational Journal of Computerized Dentistry
dcterms.bibliographicCitation.number2
dcterms.bibliographicCitation.originalpublishernameQuintessence Publishing
dcterms.bibliographicCitation.pageend124
dcterms.bibliographicCitation.pagestart115
dcterms.bibliographicCitation.pmid25098159
dcterms.bibliographicCitation.volume17
dspace.entity.typePublicationen
uzh.contributor.affiliationUniversity of Cologne
uzh.contributor.affiliationZahnarztpraxis in Frechen Königsdorf
uzh.contributor.affiliationUniversity of Zurich
uzh.contributor.affiliationCenter of Advanced European Studies and Research
uzh.contributor.affiliationFirma Sicat
uzh.contributor.affiliationUniversity of Cologne
uzh.contributor.affiliationUniversity of Cologne
uzh.contributor.authorRitter, Lutz
uzh.contributor.authorPalmer, J
uzh.contributor.authorBindl, Andreas
uzh.contributor.authorIrsen, Stefan
uzh.contributor.authorCizek, Jirka
uzh.contributor.authorKarapetian, Viktor-E
uzh.contributor.authorZöller, Joachim E
uzh.contributor.correspondenceYes
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.document.availabilitycontent_undefined
uzh.eprint.datestamp2015-01-30 14:19:38
uzh.eprint.lastmod2025-08-04 03:37:13
uzh.eprint.statusChange2015-01-30 14:19:38
uzh.harvester.ethYes
uzh.harvester.nbNo
uzh.identifier.doi10.5167/uzh-106147
uzh.jdb.eprintsId27464
uzh.oastatus.zoraClosed
uzh.publication.citationRitter, Lutz; Palmer, J; Bindl, Andreas; Irsen, Stefan; Cizek, Jirka; Karapetian, Viktor-E; Zöller, Joachim E (2014). Accuracy of chairside-milled CAD/CAM drill guides for dental implants. International Journal of Computerized Dentistry, 17(2):115-124.
uzh.publication.originalworkoriginal
uzh.publication.publishedStatusfinal
uzh.scopus.impact10
uzh.scopus.subjectsDentistry (miscellaneous)
uzh.scopus.subjectsComputer Science Applications
uzh.workflow.doajuzh.workflow.doaj.false
uzh.workflow.eprintid106147
uzh.workflow.fulltextStatusrestricted
uzh.workflow.revisions53
uzh.workflow.rightsCheckkeininfo
uzh.workflow.statusarchive
uzh.wos.impact9
Files

Original bundle

Name:
65_Bindl_Accuracy_Chair_IJCD_2014.pdf
Size:
7.58 MB
Format:
Adobe Portable Document Format
Downloadable by admins only
Publication available in collections: