Publication: Accuracy of chairside-milled CAD/CAM drill guides for dental implants
Accuracy of chairside-milled CAD/CAM drill guides for dental implants
Date
Date
Date
| cris.lastimport.scopus | 2025-08-04T03:37:13Z | |
| cris.lastimport.wos | 2025-07-12T01:33:14Z | |
| dc.contributor.institution | University of Zurich | |
| dc.date.accessioned | 2015-01-30T14:19:38Z | |
| dc.date.available | 2015-01-30T14:19:38Z | |
| dc.date.issued | 2014 | |
| dc.description.abstract | PURPOSE To describe a chairside method for producing implant guides based solely on digital data and present a first assessment of in vitro accuracy on plaster models. MATERIAL AND METHODS Twenty-four implants were planned and pilot drillings were performed according to a new protocol, which is based on the registration of CBCT and CAD/CAM data. Chairside-milled one-piece drill guides were used to transfer the virtual plan into reality. Accuracy measurements were acquired. RESULTS Chairside-milled drill guides were successfully fabricated and accuracy for pilot drillings was between 0.17 and 1.3 mm. CONCLUSION Within the limits of this experimental study, chairside-milled drill guides are feasible and do not require any preparation before CBCT scanning. | |
| dc.identifier.issn | 1463-4201 | |
| dc.identifier.scopus | 2-s2.0-84906922505 | |
| dc.identifier.uri | https://www.zora.uzh.ch/handle/20.500.14742/84370 | |
| dc.identifier.wos | 000209717200003 | |
| dc.language.iso | eng | |
| dc.subject.ddc | 610 Medicine & health | |
| dc.title | Accuracy of chairside-milled CAD/CAM drill guides for dental implants | |
| dc.type | article | |
| dcterms.accessRights | info:eu-repo/semantics/restrictedAccess | |
| dcterms.bibliographicCitation.journaltitle | International Journal of Computerized Dentistry | |
| dcterms.bibliographicCitation.number | 2 | |
| dcterms.bibliographicCitation.originalpublishername | Quintessence Publishing | |
| dcterms.bibliographicCitation.pageend | 124 | |
| dcterms.bibliographicCitation.pagestart | 115 | |
| dcterms.bibliographicCitation.pmid | 25098159 | |
| dcterms.bibliographicCitation.volume | 17 | |
| dspace.entity.type | Publication | en |
| uzh.contributor.affiliation | University of Cologne | |
| uzh.contributor.affiliation | Zahnarztpraxis in Frechen Königsdorf | |
| uzh.contributor.affiliation | University of Zurich | |
| uzh.contributor.affiliation | Center of Advanced European Studies and Research | |
| uzh.contributor.affiliation | Firma Sicat | |
| uzh.contributor.affiliation | University of Cologne | |
| uzh.contributor.affiliation | University of Cologne | |
| uzh.contributor.author | Ritter, Lutz | |
| uzh.contributor.author | Palmer, J | |
| uzh.contributor.author | Bindl, Andreas | |
| uzh.contributor.author | Irsen, Stefan | |
| uzh.contributor.author | Cizek, Jirka | |
| uzh.contributor.author | Karapetian, Viktor-E | |
| uzh.contributor.author | Zöller, Joachim E | |
| uzh.contributor.correspondence | Yes | |
| uzh.contributor.correspondence | No | |
| uzh.contributor.correspondence | No | |
| uzh.contributor.correspondence | No | |
| uzh.contributor.correspondence | No | |
| uzh.contributor.correspondence | No | |
| uzh.contributor.correspondence | No | |
| uzh.document.availability | content_undefined | |
| uzh.eprint.datestamp | 2015-01-30 14:19:38 | |
| uzh.eprint.lastmod | 2025-08-04 03:37:13 | |
| uzh.eprint.statusChange | 2015-01-30 14:19:38 | |
| uzh.harvester.eth | Yes | |
| uzh.harvester.nb | No | |
| uzh.identifier.doi | 10.5167/uzh-106147 | |
| uzh.jdb.eprintsId | 27464 | |
| uzh.oastatus.zora | Closed | |
| uzh.publication.citation | Ritter, Lutz; Palmer, J; Bindl, Andreas; Irsen, Stefan; Cizek, Jirka; Karapetian, Viktor-E; Zöller, Joachim E (2014). Accuracy of chairside-milled CAD/CAM drill guides for dental implants. International Journal of Computerized Dentistry, 17(2):115-124. | |
| uzh.publication.originalwork | original | |
| uzh.publication.publishedStatus | final | |
| uzh.scopus.impact | 10 | |
| uzh.scopus.subjects | Dentistry (miscellaneous) | |
| uzh.scopus.subjects | Computer Science Applications | |
| uzh.workflow.doaj | uzh.workflow.doaj.false | |
| uzh.workflow.eprintid | 106147 | |
| uzh.workflow.fulltextStatus | restricted | |
| uzh.workflow.revisions | 53 | |
| uzh.workflow.rightsCheck | keininfo | |
| uzh.workflow.status | archive | |
| uzh.wos.impact | 9 | |
| Files | Original bundle
65_Bindl_Accuracy_Chair_IJCD_2014.pdfview file |Download7.58 MB | |
| Publication available in collections: |