dc.description.abstract

INTRODUCTION: Subperiosteal preparation using a periosteal elevator leads to disturbances of local periosteal microcirculation. Soft-tissue damage can usually be considerably reduced using piezoelectric technology. For this reason, we investigated the effects of a novel piezoelectric device on local periosteal microcirculation and compared this approach with the conventional preparation of the periosteum using a periosteal elevator. MATERIAL AND METHODS: A total of 20 Lewis rats were randomly assigned to one of two groups. Subperiosteal preparation was performed using either a piezoelectric device or a periosteal elevator. Intravital microscopy was performed immediately after the procedure as well as three and eight days postoperatively. Statistical analysis of microcirculatory parameters was performed offline using analysis of variance (ANOVA) on ranks (p<0.05). RESULTS: At all time points investigated, intravital microscopy demonstrated significantly higher levels of periosteal perfusion in the group of rats that underwent piezosurgery than in the group of rats that underwent treatment with a periosteal elevator. CONCLUSION: The use of a piezoelectric device for subperiosteal preparation is associated with better periosteal microcirculation than the use of a conventional periosteal elevator. As a result, piezoelectric devices can be expected to have a positive effect on bone metabolism.

dc.identifier.doi10.1016/j.mvr.2014.06.003
dc.identifier.issn0026-2862
dc.identifier.scopus2-s2.0-84904633586
dc.identifier.urihttps://www.zora.uzh.ch/handle/20.500.14742/81865
dc.identifier.wos000339858000016
dc.language.isoeng
dc.subject.ddc610 Medicine & health
dc.title

Effects of a new piezoelectric device on periosteal microcirculation after subperiosteal preparation

dc.typearticle
dcterms.accessRightsinfo:eu-repo/semantics/openAccess
dcterms.bibliographicCitation.journaltitleMicrovascular Research
dcterms.bibliographicCitation.originalpublishernameElsevier
dcterms.bibliographicCitation.pageend118
dcterms.bibliographicCitation.pagestart114
dcterms.bibliographicCitation.pmid24933582
dcterms.bibliographicCitation.volume94
dspace.entity.typePublicationen
uzh.contributor.affiliationMedizinische Hochschule Hannover (MHH)
uzh.contributor.affiliationMedizinische Hochschule Hannover (MHH)
uzh.contributor.affiliationMedizinische Hochschule Hannover (MHH)
uzh.contributor.affiliationMedizinische Hochschule Hannover (MHH)
uzh.contributor.affiliationMedizinische Hochschule Hannover (MHH)
uzh.contributor.affiliationMedizinische Hochschule Hannover (MHH)
uzh.contributor.affiliationMedizinische Hochschule Hannover (MHH)
uzh.contributor.authorStoetzer, Marcus
uzh.contributor.authorFelgenträger, Dörthe
uzh.contributor.authorKampmann, Andreas
uzh.contributor.authorSchumann, Paul
uzh.contributor.authorRücker, Martin
uzh.contributor.authorGellrich, Nils-Claudius
uzh.contributor.authorvon See, Constantin
uzh.contributor.correspondenceYes
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.document.availabilitynone
uzh.document.availabilitypostprint
uzh.eprint.datestamp2014-12-30 13:10:00
uzh.eprint.lastmod2025-08-03 03:33:14
uzh.eprint.statusChange2014-12-30 13:10:00
uzh.harvester.ethYes
uzh.harvester.nbNo
uzh.identifier.doi10.5167/uzh-103102
uzh.jdb.eprintsId20366
uzh.oastatus.unpaywallgreen
uzh.oastatus.zoraGreen
uzh.publication.citationStoetzer, Marcus; Felgenträger, Dörthe; Kampmann, Andreas; Schumann, Paul; Rücker, Martin; Gellrich, Nils-Claudius; von See, Constantin (2014). Effects of a new piezoelectric device on periosteal microcirculation after subperiosteal preparation. Microvascular Research, 94:114-118.
uzh.publication.originalworkoriginal
uzh.publication.publishedStatusfinal
uzh.scopus.impact13
uzh.scopus.subjectsBiochemistry
uzh.scopus.subjectsCardiology and Cardiovascular Medicine
uzh.scopus.subjectsCell Biology
uzh.workflow.doajuzh.workflow.doaj.false
uzh.workflow.eprintid103102
uzh.workflow.fulltextStatusrestricted
uzh.workflow.revisions54
uzh.workflow.rightsCheckkeininfo
uzh.workflow.statusarchive
uzh.wos.impact15
Files

Original bundle

Name:
MVR-endf.pdf
Size:
470.14 KB
Format:
Adobe Portable Document Format
Name:
MVR.pdf
Size:
345.37 KB
Format:
Adobe Portable Document Format
Publication available in collections: