Publication:

Biodegradable sleeves for metal implants to prevent implant-associated infection: an experimental in vivo study in sheep

Date

Date

Date
2012
Journal Article
Published version

Citations

Citation copied

von Plocki, S. C., Armbruster, D., Klein, K., Kämpf, K., Zlinszky, K., Hilbe, M., Kronen, P., Gruskin, E., & von Rechenberg, B. (2012). Biodegradable sleeves for metal implants to prevent implant-associated infection: an experimental in vivo study in sheep. Veterinary Surgery, 41(3), 410–421. https://doi.org/10.1111/j.1532-950X.2011.00943.x

Abstract

Abstract

Abstract

OBJECTIVE: To evaluate biocompatibility of biodegradable sleeves containing antimicrobial agents, designed for local drug delivery to prevent implant-related infection. STUDY DESIGN: Synthetic polyester sleeves (a copolymer of glycolide, caprolactone, trimethylene carbonate, lactide) were cast as thin films. The antimicrobial agents incorporated in the sleeves included gentamicin sulfate, triclosan, or a combination of these drugs. ANIMALS: Adult sheep (n = 15). METHODS: Two limited contact dynamic compression plates (LC-DCP) with or

Metrics

Views

118 since deposited on 2012-03-01
Acq. date: 2025-11-12

Additional indexing

Creators (Authors)

  • von Plocki, S C
    affiliation.icon.alt
  • Armbruster, D
    affiliation.icon.alt
  • Klein, K
    affiliation.icon.alt
  • Kämpf, K
    affiliation.icon.alt
  • Zlinszky, K
    affiliation.icon.alt
  • Hilbe, Monika
    affiliation.icon.alt
  • Kronen, P
    affiliation.icon.alt
  • Gruskin, E
    affiliation.icon.alt
  • von Rechenberg, Brigitte
    affiliation.icon.alt

Journal/Series Title

Journal/Series Title

Journal/Series Title

Volume

Volume

Volume
41

Number

Number

Number
3

Page range/Item number

Page range/Item number

Page range/Item number
410

Page end

Page end

Page end
421

Item Type

Item Type

Item Type
Journal Article

Dewey Decimal Classifikation

Dewey Decimal Classifikation

Dewey Decimal Classifikation

Language

Language

Language
English

Publication date

Publication date

Publication date
2012

Date available

Date available

Date available
2012-03-01

Publisher

Publisher

Publisher

ISSN or e-ISSN

ISSN or e-ISSN

ISSN or e-ISSN
0161-3499

OA Status

OA Status

OA Status
Closed

PubMed ID

PubMed ID

PubMed ID

Metrics

Views

118 since deposited on 2012-03-01
Acq. date: 2025-11-12

Citations

Citation copied

von Plocki, S. C., Armbruster, D., Klein, K., Kämpf, K., Zlinszky, K., Hilbe, M., Kronen, P., Gruskin, E., & von Rechenberg, B. (2012). Biodegradable sleeves for metal implants to prevent implant-associated infection: an experimental in vivo study in sheep. Veterinary Surgery, 41(3), 410–421. https://doi.org/10.1111/j.1532-950X.2011.00943.x

Closed
Loading...
Thumbnail Image

Files

Files

Files
Files available to download:1

Files

Files

Files
Files available to download:1
Loading...
Thumbnail Image