OBJECTIVES: To test the failure load and failure mode of a novel implant-crown interface specifically designed for the fabrication of fully personalized, abutment-free monolithic zirconia CAD-CAM crowns compared to conventional implant-abutment interfaces involving prefabricated or centrally manufactured abutments for zirconia CAD-CAM crowns.
METHODS: Implants (N=48) were divided into groups (n=12) according to different implant-abutment interface designs: (1) internal implant connection with personalized, abutment-free CAD-CAM crown
Metrics
Downloads
Views
Additional indexing
Creators (Authors)
Volume
Volume
Volume
Page range/Item number
Page range/Item number
Page range/Item number
Item Type
Item Type
Item Type
In collections
Dewey Decimal Classifikation
Dewey Decimal Classifikation
Dewey Decimal Classifikation
Language
Language
Language
Publication date
Publication date
Publication date
Date available
Date available
Date available
ISSN or e-ISSN
ISSN or e-ISSN
ISSN or e-ISSN
OA Status
OA Status
OA Status
Free Access at
Free Access at
Free Access at
Publisher DOI
Metrics
Downloads
Views
Citations
Hjerppe, J., Jung, R. E., Hämmerle, C. H., Özcan, M., & Mühlemann, S. (2022). Mechanical stability of fully personalized, abutment-free zirconia implant crowns on a novel implant-crown interface. Journal of Dentistry, 121, 104121. https://doi.org/10.1016/j.jdent.2022.104121