Publication:

Mechanical stability of fully personalized, abutment-free zirconia implant crowns on a novel implant-crown interface

Date

Date

Date
2022
Journal Article
Published version

Citations

Citation copied

Hjerppe, J., Jung, R. E., Hämmerle, C. H., Özcan, M., & Mühlemann, S. (2022). Mechanical stability of fully personalized, abutment-free zirconia implant crowns on a novel implant-crown interface. Journal of Dentistry, 121, 104121. https://doi.org/10.1016/j.jdent.2022.104121

Abstract

Abstract

Abstract

OBJECTIVES: To test the failure load and failure mode of a novel implant-crown interface specifically designed for the fabrication of fully personalized, abutment-free monolithic zirconia CAD-CAM crowns compared to conventional implant-abutment interfaces involving prefabricated or centrally manufactured abutments for zirconia CAD-CAM crowns.

METHODS: Implants (N=48) were divided into groups (n=12) according to different implant-abutment interface designs: (1) internal implant connection with personalized, abutment-free CAD-CAM crown

Metrics

Downloads

4 since deposited on 2023-02-22
1last week
Acq. date: 2025-11-12

Views

1 since deposited on 2023-02-22
Acq. date: 2025-11-12

Additional indexing

Creators (Authors)

  • Hjerppe, Jenni
    affiliation.icon.alt
  • Jung, Ronald E
    affiliation.icon.alt
  • Hämmerle, Christoph Hf
    affiliation.icon.alt
  • Mühlemann, Sven
    affiliation.icon.alt

Journal/Series Title

Journal/Series Title

Journal/Series Title

Volume

Volume

Volume
121

Page range/Item number

Page range/Item number

Page range/Item number
104121

Item Type

Item Type

Item Type
Journal Article

Dewey Decimal Classifikation

Dewey Decimal Classifikation

Dewey Decimal Classifikation

Language

Language

Language
English

Publication date

Publication date

Publication date
2022-06

Date available

Date available

Date available
2023-02-22

Publisher

Publisher

Publisher

ISSN or e-ISSN

ISSN or e-ISSN

ISSN or e-ISSN
0300-5712

OA Status

OA Status

OA Status
Hybrid

Free Access at

Free Access at

Free Access at
DOI

PubMed ID

PubMed ID

PubMed ID

Metrics

Downloads

4 since deposited on 2023-02-22
1last week
Acq. date: 2025-11-12

Views

1 since deposited on 2023-02-22
Acq. date: 2025-11-12

Citations

Citation copied

Hjerppe, J., Jung, R. E., Hämmerle, C. H., Özcan, M., & Mühlemann, S. (2022). Mechanical stability of fully personalized, abutment-free zirconia implant crowns on a novel implant-crown interface. Journal of Dentistry, 121, 104121. https://doi.org/10.1016/j.jdent.2022.104121

Hybrid Open Access
Loading...
Thumbnail Image

Files

Files

Files
Files available to download:1

Files

Files

Files
Files available to download:1
Loading...
Thumbnail Image