Publication:

Non-invasive accurate measurement of arterial PCO2 in a pediatric animal model

Date

Date

Date
2013
Journal Article
Published version

Citations

Citation copied

Fierstra, J., Winter, J. D., Machina, M., Lukovic, J., Duffin, J., Kassner, A., & Fisher, J. A. (2013). Non-invasive accurate measurement of arterial PCO2 in a pediatric animal model. Journal of Clinical Monitoring and Computing, 27(2), 147–155. https://doi.org/10.1007/s10877-012-9403-8

Abstract

Abstract

Abstract

The PCO2 in arterial blood (PaCO2) is a good parameter for monitoring ventilation and acid-base changes in ventilated patients, but its measurement is invasive and difficult to obtain in small children. Attempts have been made to use the partial pressure of CO2 in end-tidal gas (PETCO2), as a noninvasive surrogate for PaCO2. Studies have revealed that, unfortunately, the differences between PETCO2 and PaCO2 are too variable to be clinically useful. We hypothesized that end-inspiratory rebreathing, previously shown to equalize PETCO2 a

Metrics

Views

97 since deposited on 2014-03-13
Acq. date: 2025-11-14

Additional indexing

Creators (Authors)

  • Fierstra, Jorn
    affiliation.icon.alt
  • Winter, Jeff D
    affiliation.icon.alt
  • Machina, Matthew
    affiliation.icon.alt
  • Lukovic, Jelena
    affiliation.icon.alt
  • Duffin, James
    affiliation.icon.alt
  • Kassner, Andrea
    affiliation.icon.alt
  • Fisher, Joseph A
    affiliation.icon.alt

Journal/Series Title

Journal/Series Title

Journal/Series Title

Volume

Volume

Volume
27

Number

Number

Number
2

Page range/Item number

Page range/Item number

Page range/Item number
147

Page end

Page end

Page end
155

Item Type

Item Type

Item Type
Journal Article

Dewey Decimal Classifikation

Dewey Decimal Classifikation

Dewey Decimal Classifikation

Language

Language

Language
English

Publication date

Publication date

Publication date
2013

Date available

Date available

Date available
2014-03-13

Publisher

Publisher

Publisher

ISSN or e-ISSN

ISSN or e-ISSN

ISSN or e-ISSN
1387-1307

OA Status

OA Status

OA Status
Closed

PubMed ID

PubMed ID

PubMed ID

Metrics

Views

97 since deposited on 2014-03-13
Acq. date: 2025-11-14

Citations

Citation copied

Fierstra, J., Winter, J. D., Machina, M., Lukovic, J., Duffin, J., Kassner, A., & Fisher, J. A. (2013). Non-invasive accurate measurement of arterial PCO2 in a pediatric animal model. Journal of Clinical Monitoring and Computing, 27(2), 147–155. https://doi.org/10.1007/s10877-012-9403-8

Closed
Loading...
Thumbnail Image

Permanent URL

Permanent URL

Permanent URL
No files available