Publication:

Two-month longitudinal study of mechanical properties of absorbable sutures used in orthopedic surgery

Date

Date

Date
2016
Journal Article
Published version
cris.lastimport.scopus2025-08-11T03:46:30Z
cris.lastimport.wos2025-07-15T01:30:36Z
dc.contributor.institutionUniversity of Zurich
dc.date.accessioned2016-10-14T14:44:39Z
dc.date.available2016-10-14T14:44:39Z
dc.date.issued2016-10-12
dc.description.abstract

This is the first study assessing the properties of large-Diameter degradable sutures relevant for orthopedicapplications over the course og in vitro incubation for 2 months. The data we present here provide guidance to the orthopedic surgeon in predicting the long-term Performance of suture materials usedeveryday in surgical practice.

dc.identifier.doi10.1186/s13018-016-0451-5
dc.identifier.issn1749-799X
dc.identifier.scopus2-s2.0-84990876593
dc.identifier.urihttps://www.zora.uzh.ch/handle/20.500.14742/121642
dc.identifier.wos000385466100001
dc.language.isoeng
dc.subject.ddc610 Medicine & health
dc.title

Two-month longitudinal study of mechanical properties of absorbable sutures used in orthopedic surgery

dc.typearticle
dcterms.accessRightsinfo:eu-repo/semantics/openAccess
dcterms.bibliographicCitation.journaltitleJournal of Orthopaedic Surgery and Research
dcterms.bibliographicCitation.number1
dcterms.bibliographicCitation.originalpublishernameBioMed Central
dcterms.bibliographicCitation.pageend7
dcterms.bibliographicCitation.pagestart1
dcterms.bibliographicCitation.pmid27729082
dcterms.bibliographicCitation.volume11
dspace.entity.typePublicationen
uzh.contributor.affiliationUniklinik Balgrist
uzh.contributor.affiliationUniklinik Balgrist
uzh.contributor.affiliationUniklinik Balgrist
uzh.contributor.authorMüller, Daniel A
uzh.contributor.authorSnedeker, Jess G
uzh.contributor.authorMeyer, Dominik C
uzh.contributor.correspondenceYes
uzh.contributor.correspondenceNo
uzh.contributor.correspondenceNo
uzh.document.availabilitypublished_version
uzh.eprint.datestamp2016-10-14 14:44:39
uzh.eprint.lastmod2025-08-11 03:46:30
uzh.eprint.statusChange2016-10-14 14:44:39
uzh.harvester.ethYes
uzh.harvester.nbNo
uzh.identifier.doi10.5167/uzh-126623
uzh.jdb.eprintsId15643
uzh.oastatus.unpaywallgold
uzh.oastatus.zoraGold
uzh.publication.citationMüller, Daniel A; Snedeker, Jess G; Meyer, Dominik C (2016). Two-month longitudinal study of mechanical properties of absorbable sutures used in orthopedic surgery. Journal of Orthopaedic Surgery and Research, 11(1):1-7.
uzh.publication.freeAccessAtpubmedid
uzh.publication.originalworkoriginal
uzh.publication.publishedStatusfinal
uzh.scopus.impact49
uzh.scopus.subjectsSurgery
uzh.scopus.subjectsOrthopedics and Sports Medicine
uzh.workflow.doajuzh.workflow.doaj.true
uzh.workflow.eprintid126623
uzh.workflow.fulltextStatuspublic
uzh.workflow.revisions63
uzh.workflow.rightsCheckoffen
uzh.workflow.statusarchive
uzh.wos.impact38
Files

Original bundle

Name:
__int.balgrist.ch_Data$_Home2_FrustaciD_System_Desktop_2016_Müller_Two-month longitudinal study of mechanical properties of absorbable sutures used in orthopedic surgery_JOSR.pdf
Size:
626.98 KB
Format:
Adobe Portable Document Format
Publication available in collections: