Barth, B. K., Cornelius, A., Nanz, D., Eberli, D., & Donati, O. F. (2015). Diffusion-weighted imaging of the prostate: image quality and geometric distortion of readout-segmented versus selective-excitation accelerated acquisitions. Investigative Radiology, 50(11), 785–791. https://doi.org/10.1097/RLI.0000000000000184

Abstract

Abstract

Abstract

OBJECTIVE: To compare image quality and geometric distortion between readout-segmented diffusion-weighted imaging (rs-DWI) and selective-excitation accelerated reduced-field of view (FOV) DWI (sTX-DWI) of the prostate. MATERIALS AND METHODS: Sixty-five patients underwent 3-T MRI of the prostate including rs-DWI and sTX-DWI (b values, 0, 50, and 1000 seconds/mm$^2$; FOV, 150 × 150 mm$^2$ and 77 ×150 mm for rs-DWI and sTX-DWI; slice thickness, 3 mm; acquisition time, 8:18 min and 1:37 min for rs-DWI and sTX-DWI). Two readers evaluated a

Additional indexing

Creators (Authors)

  • Barth, Borna K
    affiliation.icon.alt
  • Cornelius, Alexander
    affiliation.icon.alt
  • Nanz, Daniel
    affiliation.icon.alt
  • Eberli, Daniel
    affiliation.icon.alt
  • Donati, Olivio F
    affiliation.icon.alt

Journal/Series Title

Journal/Series Title

Journal/Series Title

Volume

Volume

Volume
50

Number

Number

Number
11

Page Range

Page Range

Page Range
785

Page end

Page end

Page end
791

Item Type

Item Type

Item Type
Journal Article

Dewey Decimal Classifikation

Dewey Decimal Classifikation

Dewey Decimal Classifikation

Keywords

This is a non-final version of an article published in final form in Barth et al: Diffusion-Weighted Imaging of the Prostate: Image Quality and Geometric Distortion of Readout-Segmented Versus Selective-Excitation Accelerated Acquisitions, 2015, Investigative Radiology.

Language

Language

Language
English

Publication date

Publication date

Publication date
2015-07-02

Date available

Date available

Date available
2015-07-16

Publisher

Publisher

Publisher

ISSN or e-ISSN

ISSN or e-ISSN

ISSN or e-ISSN
0020-9996

OA Status

OA Status

OA Status
Green

PubMed ID

PubMed ID

PubMed ID

Citations

Citation copied

Barth, B. K., Cornelius, A., Nanz, D., Eberli, D., & Donati, O. F. (2015). Diffusion-weighted imaging of the prostate: image quality and geometric distortion of readout-segmented versus selective-excitation accelerated acquisitions. Investigative Radiology, 50(11), 785–791. https://doi.org/10.1097/RLI.0000000000000184

Green Open Access
Loading...
Thumbnail Image

Files

Files

Files
Files available to download:1

Files

Files

Files
Files available to download:1
Loading...
Thumbnail Image